Operation Starting Control

The system carries out the following control at the beginning to conduct every functional parts
properly.
1. Opening the front panel fully
2. Output of the ∆ D signal after the front panel starts moving
3. Opening the flap fully after the front panel opens fully
4. Making the fan rotate when the flap passes over the fan-banned area
Control Flow
Timing Chart
Function and Control
Opening the front panel
fully
Opening the flap fully
OFF
Fully close
Front
panel
Fully open
Fully open
Flap
Fan-banned area
Fully close
ON
Fan
OFF
Output
∆D
∆0
ON
Force supply
(from the
outdoor unit)
OFF
Start
Making the fan rotate when
the flap passes over the
fan-banned area
Running
Start
Operation
starting control
Main Functions
Output of the ∆D signal after
the front panel starts moving
(R3311)
ON
Under running control
Under operation mode control
Under operation mode control
The outdoor unit provides force
when it receives the ∆D signal.
(R11910)