Indoor Unit
Step
3. Remove the fan motor.
Remove the screw and
1
remove the fan motor.
144
Procedure
SiBE041012
Points
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm of
play between the side face
of the rotor and the bottom
frame.
Side face of
Side face of rotor
bottom frame
5 mm
Removal Procedure
(R2808)