Rexroth Ce Settings; General Information; Ethernet Adapter - Bosch Rexroth IndraControl VEH 30.1 Project Planning Manual

Hand-held terminal
Hide thumbs Also See for Rexroth IndraControl VEH 30.1:
Table of Contents

Advertisement

48/68
Bosch Rexroth AG | Electric Drives
Software
9.4

Rexroth CE Settings

9.4.1

General Information

9.4.2

Ethernet Adapter

Obtain an IP address via DHCP
and Controls
gram with the desktop icon ToolsTouch Calibration or with the start menu
Start Programs Touch Calibration.
In case of an operating system update the program automatically starts.
Touch exactly the four calibration points one after each other with a touch pen
(red point at the arrowhead). After having actuated the last calibration point, the
display changes to the Windows desktop after a waiting time of approx. five
seconds. In this desktop you can verify the proper calibration of the touch
screen and confirm the settings with <OK>.
Fig.9-3:
Touch screen calibration of the IndraControl VEH 30.1
You can do all basic settings of the IndraControl VEH 30.1 devices with the tool
"Rexroth CE Settings". You can start this tool with the desktop icon <Rexroth
CE Settings> or with the start menu <Start> <Programs> <Tools> <Rexroth CE
Settings>. In case of an operating system update the tool automatically starts.
The "Rexroth CE Settings" of the IndraControl VEH 30.1 are retrieved from the
connection module IndraControl VAC 30.2, see
IndraControl VEH 30.1" on page
When commissioning the IndraControl VAC 30.2 for the first time,
all values are set to default.
In the register "Ethernet-Adapter" the Ethernet adapter of the IndraControl VEH
30.1 is configured.
Fig.9-4:
Rexroth CE Settings: Ethernet Adapter
Automatic assignment of the network parameters via DHCP.
Rexroth IndraControl VEH 30.1 | Project Planning Manual
35.
chapter 7 "Pin Assignment of