  • Page 1 OWNER’S MANUAL Split Air Conditioner Vip Inverter Series МОДЕЛИ: CH-S09FTXHV-B CH-S12FTXHV-B CH-S18FTXHV-B For proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com...
  • Page 2 Specialties note Matching instructions This model adopts RF remote control. The remote controller shall be matched with the air conditioner before operation, otherwise the remote control will be invalid. Before operation, please read the instructions in this page carefully and then do the corresponding matching operation. Note Please done the following operation within 2m from the unit.
  • Page 3: Table Of Contents

    Content Operation Notices Precautions......................1 Parts name ......................6 Screen Operation Guide Buttons on remote controller ................7 Introduction for icons on display screen ............... 7 Introduction for buttons on remote controller ............8 Function introduction for combination buttons ............14 Operation guide ....................15 Replacement of batteries in remote controller ............15 Operation of Smart Control (Smart Phone, Tablet PC) ........
  • Page 4: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 6 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 7 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 8 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 9: Parts Name

    Parts name Indoor Unit air inlet panel power wire filter horizontal louver air outlet remote controller power display tem.display NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 10: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button +/- button Cool button Heat button Fan button I FEEL button up down swing button Mode button Left right swing button T-ON/T-OFF button Clock button Humidity button/Health button X-fan button Air button Light button Sleep button WIFI button Introduction for icons on display screen...
  • Page 11: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: ● After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller. ●...
  • Page 12 Introduction for buttons on remote controller I FEEL button Press this button to start I FEEL function and " " will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature.
  • Page 13 Introduction for buttons on remote controller ● When selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature can’t be adjusted and will not be displayed as well. Press "FAN" button can adjust fan speed. Press " "...
  • Page 14 Introduction for buttons on remote controller T-ON/T-OFF button ● T-ON button “T-ON” button can set the time for timer on. After pressing this button, " " icon disappears and the word “ON" on remote controller blinks. Press “+” or “-”button to adjust T-ON setting.
  • Page 15 Introduction for buttons on remote controller Humdity/health button Press this button to select your required operation mode. cancel INTELLIGENT INTELLIGENT Note:there is no this function for this unit. If press this button,the main unit will click, but it also runs under original status. X-FAN button Pressing this button in COOL or DRY mode, the icon "...
  • Page 16 Introduction for buttons on remote controller In Sleep 1 and Sleep 2, the air conditioner will run according to a group of presetting ● temperature curves. Sleep 3 - the sleep curve setting under DIY Sleep mode: ● (1) Under Sleep 3 mode, long press "AIR" button, the remote controller will enter the setting of personalized sleep.
  • Page 17: Function Introduction For Combination Buttons

    Function introduction for combination buttons About X-FAN function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould. 1. Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 2 min.
  • Page 18: Operation Guide

    Operation guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press "+" or " - " button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 19: Operation Of Smart Control (Smart Phone, Tablet Pc)

    Operation of Smart Control (Smart Phone, Tablet PC) Special Function How to operate AC or auxiliary device with smart phone or tablet PC after matching: First of all: before using smart connection function, please make sure your smart phone or tablet computer uses the standard Android or iOS operating system. Please refer to the application program for the specific version.
  • Page 20 Operation of Smart Control (Smart Phone, Tablet PC) 2. Turn on the AC WiFi: Turn the AC on. First, make sure the remote controller is matched. Then, long-press “WiFi” button on the remote controller for at least 3 seconds. If WiFi icon is shown, it means the WiFi function is turned on.
  • Page 21 Operation of Smart Control (Smart Phone, Tablet PC) Attention: please change the name and key of the network during the first setting! 6. Left-slide the bottom function bar to “Settings” and click it to enter into internet setting interface. Click “Network Setting”, and input user name and password (the defaulted user name and password is admin) in the “Login”...
  • Page 22 Operation of Smart Control (Smart Phone, Tablet PC) 9. Enter into the software interface again. Meanwhile, the short-distance remote control setting for your air conditioner is finished. How to reset the AC WiFi module: Turn unit off with the remote controller and disconnect the power of AC. Then re-connect the power.
  • Page 23 Operation of Smart Control (Smart Phone, Tablet PC) Function Introduction on Main Interface 1. Mode: It used for setting operation mode for air conditioner. You can select “Auto”, “Cooling”, “Drying”, “Fan” or “Heating” according to your requirement. Please refer to the part of remote controller for the detailed operation.
  • Page 24 Operation of Smart Control (Smart Phone, Tablet PC) Key Functions Instruction of Application Software 1. Preset: It’s with Timer On and Timer Off function. User can set Timer On and Timer Off according to actual individual requirement. 2. Functions: After entering setting interface, you can turn on or turn off Light, Purify, X-fan and Turbo functions and set Silent, Humidify, Air exchange and other modes.
  • Page 25 Operation of Smart Control (Smart Phone, Tablet PC) 4. Advanced: After entering advanced interface, you can set Sleep curve, Regional Swing, Noise and Power saving. ● Sleep curve: Sleep curve includes DIY mode, Traditional mode, Expert mode and Siesta mode. Under DIY mode, you can set temperature and time. Under auto mode and fan mode, sleep curve function can’t be turned on.
  • Page 26 Operation of Smart Control (Smart Phone, Tablet PC) ● Noise: The noise-customized function for indoor unit can be adjusted according to the actual individual requirement. The detailed adjustment range is different for different models, which is decided by indoor unit. ●...
  • Page 27: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 28 Clean and maintenance Open panel Open the panel into a certain ● Use dust catcher or water to angle(less than 60°, do not open the panel too forcibly) along the arrow direction from the two the water (below 45℃ ) to clean sides of panel.
  • Page 29 Clean and maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 30: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity,stable the plug after about 3min, and voltage)?
  • Page 31 Malfunction analysis Phenomenon Check items Solution ● Power failure? ● Wait until power recovery. ● Is plug loose? ● Reinsert the plug. ● Air switch trips off or fuse is ● Ask professional to replace burnt out? air switch or fuse. Air condit- ●...
  • Page 32 Malfunction analysis Phenomenon Check items Solution ● Whether there’s odour source, ● Eliminate the odour source. Odours are such as furniture and cigarette, emitted ● Clean the filter. etc. ● Whether there’s interference, ● Disconnect power, put back Air conditioner such as thunder, wireless power, and then turn on the operates nor-...
  • Page 33 Malfunction analysis Error Code ● When air conditioner status is abnormal, temperature indictor on indoor unit will ation of error code. Error code Troubleshooting It can be eliminated after restarting the unit. If not , please It can be eliminated after restarting the unit. If not , please It can be eliminated after restarting the unit.
  • Page 34: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm At least 15cm Space to the wall...
  • Page 35: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 36: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 37: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 38 Installation of indoor unit Indoor outdoor Note: ● Pay attention to dust prevention and take relevant safety measures when Φ55 opening the hole. 5-10 ● The plastic expansion particles are not provided and should be bought locally. Step four: outlet pipe 1.
  • Page 39 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench Φ 6 15~20 Φ 9.52 30~40 union nut Φ 12 45~55 pipe Φ 16 torque wrench 60~65 Φ 19 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 40 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole of indoor unit and then pull it out from the front side. power connection wire 3. Remove the wire clip; connect the power connection wire to the wiring terminal with wire clip.After finishing wiring of 18K unit, clamp the grounding wire (yellow- green wire) into the wire-crossing groove as shown in the following figure, in order to avoid pressing the wire when closing the electric box cover.
  • Page 41 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 42: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas liquid valve piezometer valve and the nut of refri- gas valve gerant charging vent. refrigerant charging 2. Connect the charging hose valve cap vent of piezometer to the refri- gerant charging vent of gas nut of refrigerant...
  • Page 43: Check After Installation

    Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling Have you done the refrigerant leakage test? (heating) capacity.
  • Page 44: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe and max. high difference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- capacity...
  • Page 45 Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m) Φ6 Φ9.52 or Φ12 Φ6 or Φ9.52 Φ16 or Φ19 Φ12 Φ19 or Φ22.2 Φ16...
  • Page 46: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ● Confirm the pipe length according to ● Expand the port with expander. the distance of indoor unit and hard outdoor unit.
  • Page 47 Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com E-mail: info@cooperandhunter.com 66160000152...
  • Page 48 РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР СИСТЕМЫ СПЛИТ VIP INVERTER СЕРИЯ МОДЕЛИ : CH-S09FTXHV-B CH-S12FTXHV-B CH-S18FTXHV-B Пожалуйста, внимательно изучите данное руководство перед началом работы Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com...
  • Page 49 Особенности Синхронизация Smart-пульта ДУ Данная модель оснащена Smart-пультом дистанционного управления. Пульт дистанционного управления должен соответствовать модели кондиционера, в противном случае управление будет невозможным. Примечани я Пожалуйста, выполня йте следующие операции в пределах 2м от у стройства . В процессе настройки , пожалуйста, держите пульт дистанционного управления и...
  • Page 50 Меры предосторожности Пожалуйста, прочитайте следующее прежде, чем использовать оборудование! ПРЕДУПРЕЖДЕНИЕ ★ ★ ★ При появлении запаха Не касайтесь Предохраняйте от дыма немедленно оборудования повреждений обесточьте кондиционер мокрыми руками электрический кабель и и свяжитесь с сервисным кабель межблочной центром связи. Если изоляция кабеля...
  • Page 51 Меры предосторожности ★ Убедитесь, Для собственной ★ Устанавливайте ★ что оборудование безопасности отключайте наиболее подходящую надежно заземлено кондиционер от источника температуру питания перед обслуживанием, ремонтом и чисткой, а также если планируете не Установить темп. использовать его в помещении на 5 °С ниже, чем на длительное...
  • Page 52 Меры предосторожности ★ ★ Не используйте кабель со скрутками Для изменения направления и поврежденный кабель. Если кабель горизонтального воздушного потока поврежден, пожалуйста, свяжитесь с используйте пульт дистанционного сервисным центром для его замены управления Вертикальные Горизонтальные жалюзи жалюзи ★ ★ ★ Не...
  • Page 53 Название частей кондиционера Вход воздуха Внутренний блок Выход воздуха питание темп.дисплей ⑴ Провод питания ⑵ Пульт управления ⑶ Передняя панель ⑷ Фильтр ⑸ Наружный блок Горизонт. жалюзи ⑹ Стенная проходка Вход воздуха ⑺ Изоляцион. лента ⑻ Соединит. провода ⑼ Слив конденсата ⑽...
  • Page 54 Пульт управления Нажмите для запуска и остановки работы Нажмите для понижения температуры Нажмите для повышения температуры Нажмите для выбора режима работы (AUTO/COOL/DRY/FAN/HEA Автоматический, Осушение, Обогрев. Охлаждение, Вентиляция, COOL (режим “Охлаждения”) HEAT (режим “Обогрева”) Нажмите для изменения скорости вращения вентилятора I FEEL Нажмите...
  • Page 55 Пульт управления Скорость вентилятора Сигнал ностроек Operation mode Батарея “Авто” Влажность WIFI ”Охлаждение” INTELLIGENT Температура Режим “Здоровье” “Осушение” Настройки темпер. ”Вентилятор” ”Обогрев” Вверх/вниз качание Задать время Влево/вправо качание обогрев 8°C HOUR ON OFF детский змок Turbo режим I feel функция X-FAN функция...
  • Page 56 Пульт управления FAN SPEED Холодная плазма Humidity Каждое нажатие кнопки FAN Появляется при нажатии кнопки /Health и активации режима. изменяет скорость вращения вентилятора кондиционера AUTO-LOW-MED-HIGH (Автоматическая – Низкая – X-FAN – Средняя – Высокая). Появляется при нажатии кнопки X-FAN и активации режима. I FEEL Для...
  • Page 57: Cool (Режим "Охлаждения")

    Пульт управления Описание пульта управления ON/OFF Нажмите кнопку для включения или выключения кондиционера. При включении кондиционера наЖК-дисплее внутреннего блока знак индикации горит зеленым цветом. Нажмите кнопку для понижения желаемой температуры в помещении. Удерживание кнопки,нажатой в течение 2 секунд, быстро понизит значение устанавливаемой...
  • Page 58: Air

    Пульт управления Описание пульта управления 9-10 SWING Нажмите кнопку установки угла подачи воздуха в помещение. Каждое нажатие изменяет установку угла в последовательности, как показано на рисунке: T - ON | T- OFF 11-12 При нажатии на кнопку TIMER ON устанавливается функция включения кондиционера по таймеру.
  • Page 59: Wi-Fi

    Пульт управления X-FAN Нажмите на кнопку X-FAN в режимах COOL (Охлаждение) или DRY (Осушение). На дисплее появится значок , и кондиционер продолжит осушать вентилятором внутренний блок в течение следующих 10 минут, даже если вы выключите блок с пульта управления. В режиме энергосбережения...
  • Page 60 Пульт управления Комбинация «+» и «-» Одновременное нажатие кнопок «+» и «–» блокируют кнопки пульта управления. . Повторное нажатие снимает блокировку. На дисплее появляется значок Комбинация MODE и «-» Одновременное нажатие кнопок MODE и «–» переключает единицы измерения температуры между градусами Цельсия и Фаренгейта. Подсветка...
  • Page 61 Интеллектуальное управление (Смартфон, Планшет) Как работать с вспомогательными устройствами как смартфон или планшетный ПК после сопоставления: во-первых: перед использованием смарт-функции, убедитесь, что ваш смартфон или планшетный компьютер использует стандартный Android или iOS операционную систему. Этот кондиционер можно подключить к 4-м смартфонам или планшетам одновре- менно.
  • Page 62 Интеллектуальное управление (Смартфон, Планшет) 2. Включите WiFi: Нажмите кнопку “WiFi” на пульте дистанционного управления. Если высветилась иконка WiFi следовательно функция активна. 3. Введите WiFi настройки на телефоне и выполните поиск по беспроводной сети с именем G-xxxxxxxx. Рассмотрим G-A0B40030 в качестве примера. Подключитесь...
  • Page 63 Интеллектуальное управление (Смартфон, Планшет) Внимание: пожалуйста, измените имя и ключ сети во время первой настройки! 6. Слева-слайд нижней функциональной панели “параметры” - щелкните по ней, чтобы войти в интернет настройки интерфейса. Нажмите кнопку “Настройка сети”, и введите имя пользователя и пароль в поле “логин” в диалоговом...
  • Page 64 Интеллектуальное управление (Смартфон, Планшет) 9. Войдите снова в программное обеспечение интерфейса. Установки дистанционного управления для кондиционера на короткие расстояния завершены. Как перезагрузить Wi-Fi модуль: Выключите устройство с помощью пульта дистанционного управления и отсоедините кабель питания переменного тока. Затем снова подключите кабель...
  • Page 65 Интеллектуальное управление (Смартфон, Планшет) Введение по функциям на главном интерфейсе 1. Mode: используется для установки режима работы кондиционера. Вы мо- жете выбрать “Авто”, “Охлаждение”, “Осушитель”, “Вентилятор” или “Обогрев”. 2. Temperature: установить температуру в помещении в соответствии с вашими требованиями. 3. Fan Speed: регулирование скорости вентилятора и соответственно уровеня...
  • Page 66 Интеллектуальное управление (Смартфон, Планшет) Инструкция по применению основных функций программного обеспечения 1. Preset: Пользователь может установить включение и выключение Тайме- ра по индивидуальным требованиям. 2.Functions: после ввода в интерфейс настроек, активны опции вкл. или выкл. свет, очистка, вентилятор, Turbo режим, увлажнение, воздухообмена. Электрический...
  • Page 67 Интеллектуальное управление (Смартфон, Планшет) 4. Advanced: После настроек интерфейса можно установить режим энергосбережения. ● Sleep curves (Ночной режим): можно самостоятельно задать тем- пературу и режим вентилятора. ● Regional Swing: после выбора опции “Regional Swing”, пользователь может указать площадь помещения. Нажимая кнопку “Air flow position”, пользователь...
  • Page 68 Интеллектуальное управление (Смартфон, Планшет) ● Noise: уровень шума внутреннего блока можно скорректировать в соответствии с индивидуальными требованиями. Диапазон регулировки разный для разных моделей. ● Power saving: после включения режима энергосбережения кондиционер определит температуру в помещении и температуру наружного воздуха автоматически. Возможно регулировать частоту вращения вентилятора и температуру...
  • Page 69 Аварийное включение Аварийное включение Если пульт дистанционного управления потерян или поврежден, вы можете воспользоваться кнопкой включения/выключения кондиционера, расположенной на внутреннем блоке под лицевой панелью. После включения кондиционер будет работать в режиме AUTO и менять скорость вращения вентилятора автоматически. Алгоритм работы кондиционера...
  • Page 70 Очистка и уход за оборудованием Внимание Отключите электропитание перед обслуживанием и ремонтом. Не брызгайте водой на блок для чистки из-за вероятности короткого замыкания. Протирайте блок сухой тряпкой или слегка влажной тряпкой, смоченной водой или легким раствором неагрессивного моющего средства. Не используйте растворители и абразивные моющие средства. Чистка...
  • Page 71 Очистка и уход за оборудованием Проверьте перед использованием ① Убедитесь, что ничего не мешает забору и подаче воздуха. ② Проверьте батарейки пульта управления. ③ Проверьте крепежные кронштейны наружного блока на отсутствие повреждений. Обслуживание перед использованием ① Отключите электропитание. ② Очистите фильтры и корпус наружного и внутреннего блоков. ③...
  • Page 72 Проблемы и их решения Внимание! Не ремонтируйте кондиционер самостоятельно. Для обслуживания и ремонта кондиционера обращайтесь в специализированные сервисные центры. Неправильный ремонт или обслуживание могут привести к короткому замыканию, пожару или поражению электрическим током. Пожалуйста, перед обращением в сервисный центр проверьте нижеприведенные моменты.
  • Page 73 Проблемы и их решения Явление Неисправность Блок не включается. Есть ли электропитание? Вставлена ли вилка в розетку? Не отключен ли автомат токовой защиты? Возможно, напряжение электропитания слишком низкое или высокое (это должны проверить специалисты). Проверьте, может быть, выставлена работа выключен автомат по...
  • Page 74 Проблемы и их решения Я в л е н и е Н е и п с р а в н о с ь т Нет подачи воздуха из внутреннего блока. В режиме обогрева, если температура теплообменника внутреннего блока слишком низкая, вентилятор не подает воздух в помещение, чтобы...
  • Page 75 Советы по эксплуатации Охлаждение Описание Кондиционер воздуха забирает тепло в помещении и отводит через наружный блок, таким образом понижая температуру в помещении. Текущая холодопроизводительность зависит от температуры наружного воздуха. Защита от обмерзания Если кондиционер работает в режиме охлаждения при низкой температуре окружающего воздуха, теплообменник...
  • Page 76 Советы по эксплуатации Диапазон работы оборудования На улице, DB/WB °C В помещении, DB/WB °C 32/23 54/26 Макс. при охлаждении 27/- 24/18 Макс. при обогреве Оборудование может работать в режиме охлаждения при наружной температуре в диапазоне от 18°С до 54°С, а в режиме обогрева в диапазоне -30°С до 24°С. Энергосбережение...
  • Page 77 Прочтите перед установкой Внимание! 1. Оборудование должно устанавливаться специалистами, имеющими соответствующие лицензии и сертификаты, строго соблюдая все требования и нормы безопасности, а также требования данной инструкции. 2. Перед установкой обратитесь в местное представительство торговой марки или авторизованную компанию-установщик. Если оборудование было установлено неавторизованной компанией, то ошибки...
  • Page 78 Прочтите перед установкой Выбор места установки внутреннего блока 1. Убедитесь, что ничего не препятствует входящим и исходящим потокам воздуха кондиционера. 2. Выберите место, где сконденсированная вода будет отводиться беспрепятственно и легко. выполнить соединения с наружным блоком. 3. Выберите место, недоступное детям. 4.
  • Page 79 Прочтите перед установкой Автомат токовой Модель кондиционера защиты 10 A 16 A 25 A Примечание: 1. Убедитесь в надежности подключения кабеля питания и заземления. убедитесь, что выполненное подключение соответствует электросхеме. 2. Ошибка в подключении может привести к короткому замыканию или пожару. Требования...
  • Page 80 Схема установки Схема установки Расстояние до потолка Более 15 см Расстояние до стены Более 15 см Более 15 см Расстояние до стены Сторона выхода воздуха Расстояние до пола Расстояния необходимые для правильного выбора места установки оборудования, включающие минимальные расстояния до препятствий Расстояние...
  • Page 81 Установка внутреннего блока Установка монтажной пластины 1. Монтажная пластина должна быть установлена строго горизонтально. Это важно, т.к. в конструкции блока предусмотрен наклон ванночки нормального отвода конденсата. Если блок не установлен горизонтально, конденсат может не отводиться правильно. 2. Закрепите монтажную пластину на стене при помощи винтов и дюбелей. 3.
  • Page 82 Установка внутреннего блока Подключение межблочного кабеля Подключение 1. Откройте лицевую панель. к наружному блоку 2. Снимите крышку клеммной колодки. 3. Протяните межблочный кабель с задней части блока через отверстие. 4. Подключите питание к соответствующим Внутренний клеммам. 2 3L блок 5. Закройте крышку клеммной колодки. 6.
  • Page 83 Установка внутреннего блока Подключение фреонопровода 1. Развальцуйте подключаемый фреонопровод. Совместите центры трубопровода и патрубка наружного блока. Трубопровод 2. Накрутите руками гайку, затем при помощи внутреннего блока Коническая гайка двух гаечных ключей затяните место соединения с усилием, указанным в таблице ниже. Ключ...
  • Page 84 Установка наружного блока Электрические подключения Крышка 1. Снимите крышку клеммной колодки с правой стороны наружного блока. 07; 09; 12 2. Зачистите кабель. Подключите кабель, N 2 4 5 соблюдая маркировку. 3. Закрепите межблочный кабель при помощи фиксирующей скобы. Подключение к внутреннему блоку 4.
  • Page 85 Проверка после установки перед первым пуском Проверка после установки Что проверить Возможные неисправности Блок может упасть, издавать шум или Блок надежно установлен? вибрацию Снижается эффективность работы Отсутствуют утечки хладагента? Конденсат может протекать Надежна теплоизоляция? Конденсат отводится нормально? Возможны протечки Электропитание соответствует Возможен...
  • Page 86 Установка и обслуживание дополнительного фильтра Установка опционального фильтра Одновременно с двух сторон подденьте пальцами и откройте лицевую панель. Затем вытащите воздушные фильтры как показано на рис. а Рис. a Рис. б Вставьте опциональный фильтр в Фильр специальные пазы на воздушном фильтре как...
  • Page 87 Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com E-mail: info@cooperandhunter.com 66160000152...