Error correction

8.3 Firmware update via WBM or CLI not possible

With SINEC PNI
Follow the steps below to reset the device parameters to the factory settings with the SINEC PNI:
1. Select the device whose parameters you want to reset.
2. Click the "Reset device" button.
3. Select the "Reset to factory settings" option in the following dialog.
Via the configuration
You will find detailed information on resetting the device parameters using the WBM and CLI in
the configuration manuals:
• Web Based Management, section "Restart"
• Command Line Interface, section "Reset and Defaults"
8.3
Firmware update via WBM or CLI not possible
Cause
If there is a power failure during the firmware update, it is possible that the device is no longer
accessible using Web Based Management or the CLI.
When pressing the button, make sure you adhere to the instructions in the section "Reset button
(Page 27)".
Solution
You can then also assign firmware to a SCALANCE W using TFTP.
Follow the steps below to load new firmware using TFTP:
1. Turn off the power to the device.
2. Now press the Reset button and reconnect the power to the device while holding down the
button.
3. Hold down the button until the red fault LED (F) starts to flash after approximately 2 seconds.
4. Now release the button. The bootloader waits in this state for a new firmware file that you can
download by TFTP.
5. Connect a PC to the SCALANCE W over the Ethernet interface.
6. Assign an IP address to the SCALANCE W with the SINEC PNI.
7. Open a DOS box and change to the directory where the file with the new firmware is located
and then execute the command "tftp -i <ip address> PUT <firmware>". As an alternative, you
can use a different TFTP client.
8. Close the cover to ensure that the device is closed and water and dust proof.