5.1. Functional test

BEKOMAT
8/9
®
Check normal function
To check the solenoid valve, press the TEST button briefly (approx. 2 sec.).
 Red LED "Alarm" flashes, yellow LED "Valve" lights up
 Valve opens for condensate discharge
Test fault signal
To test the solenoid valve, shut off the condensate inlet and press the TEST button for
approx. 1 minute.
 Alarm relay switches
Release the TEST button
 BEKOMAT
returns to normal function
®
Open condensate inlet again!
Minimum operating pressure 0.5 bar!