Communication Protocol - Version 2.0; Converter Tp-11 Transmits The Following Types Of Packets; Packet With Current Readings - Vega Absolute TP-11 User Manual

Lorawan converter
Hide thumbs Also See for TP-11:
Table of Contents

Advertisement

Vega TP-11 / User Manual
4 COMMUNICATION PROTOCOL – version 2.0
This part describes the TP-11 data exchange protocol with LoRaWAN
In fields consisting of several bytes, the little-endian byte order is used

CONVERTER TP-11 TRANSMITS THE FOLLOWING TYPES OF PACKETS

1. Packet with current readings

From connected heat meter, sent regularly or by the request or by the one of "Reason
of sending message" field events.
Size in bytes
Field description
1 byte
Packet type, this packet == 1
1 byte
Battery level, %
Over limits («0» – there is no, «1» - there is)
1 byte
Time of current readings in that packet (unixtime UTC)
4 byte
1 byte
Current device temperature
2 bytes
Current low threshold (mА*100)
2 bytes
Current high threshold (mА*100)
1 byte
Reason of sending message
1 byte
TP-11 inputs/outputs state
2 bytes
Measurement current of connected sensor (mA*100)
"Reason of sending message" field codes
Code
0x00
0x01
0x02
0x03
0x04
0x05
"Inputs/outputs state" bit field decoding
Bits
Field description
0 bit
Power (0 – battery, 1 – external)
1 bit
Security input 1 (0 - unclosed, 1 – closed)
2 bit
Security input 2 (0 - unclosed, 1 – closed)
3 bit
Output 1 (0 – off, 1 – on)
4 bit
Output 2 (0 – off, 1 – on)
5 bit
reserve (always 0)
Revision 12 of 12 October 2021
Value
Sending packet by the time
By the security input 1 triggering
By the security input 2 triggering
External power state was change
Measurement is out of the specified limits
Transmitting by the request
network.
®
Data type
uint8
uint8
uint8
uint32
int8
uint16
uint16
uint8
uint8
uint16
17