CONTACTS
Converter has 10 contacts, see table below:
Contact
Designation on the board
1
OUT_2
2
OUT_1
3
+VPWR
Ʇ
4
5
CL-
6
CL+
7
COUNT_2
Ʇ
8
9
COUNT_1
Ʇ
10
Ʇ
Ground
contacts 8 and 10 are used for connection of security inputs COUNT_1 and
COUNT_2.
Security inputs of the device are used to connect circuits with the following types of
NO contacts:
reed switch (Herkon);
mechanical pushbutton;
open-drain output.
While security input connected the device monitors its state change (closure/unlocking
or both of it – depend on the settings). Should the security input triggering, the device is
activated and sends an alarm message to the network.
12
Description
Open-drain output 2
Open-drain output 1
Power "+"
Power "-"
4-20 mA "-"
4-20 mA "+"
Security input 2
Ground
Security input 1
Ground
Revision 12 of 12 October 2021
Vega TP-11 / User Manual