Error Detection - Toshiba TS3000 Series Instruction Manual

Hide thumbs Also See for TS3000 Series:
Table of Contents

Advertisement

series Robot Controller
4.

Error Detection

• 8-353 Field bus Parameter error
The field bus parameter set value is wrong. Reset the parameter and then turn
the power supply off, then on again.
• 8-354 Field bus Offline
The controller and master device side are offline status. This error will be
retained until changed to an online status. This error brings the moving robot to
an emergency stop.. Check to find out the detailed causes for the offline status
on the field bus master device side.
• 8-355 Field bus Board error
There has been a discrepancy between the set parameter and the installed
printed board. Alternatively, the printed board has not been installed. Reset the
parameter and then turn the power supply off, then on again.
FIELD BUS SLAVE FUNCTION MANUAL
- 26 -
STE 80756