Ambient Conditions - FineTek SIS Operation Manual

Sanitary intelligent level switch
Hide thumbs Also See for SIS:
Table of Contents

Advertisement

6. Ambient Conditions

Normal type (Standard type / Extension type / Mini type)
Storage temperature: -40°C ~ 85°C (-40°F ~ 185°F)
Ambient temperature:-40°C ~ 85°C (-40°F ~ 185°F)
Medium temperature: Continuous; max.100°C
@ ambient temperature -40°C~85°C (-40°F~185°F)
Short time(1hr); max.150°C (Mini type: max.135°C)
@ ambient temperature -40°C~60°C (-40°F~140°F)
Power supply: 18 VDC ~ 30 VDC
Output load current: Max. 100 mA
Rear install type
Storage temperature: -40°C~85°C (-40°F~185°F)
Ambient temperature: -40°C~80°C (-40°F~176°F)
Medium temperature: -40°C~80°C (-40°F~176°F)
Power supply: 18 VDC~30 VDC
Output load current: Max, 100 mA
Explosion-proof type
Storage temperature: -20°C ~ 85°C(-4°F ~ 185°F)
Ambient temperature: -20°C ~ 70°C(-4°F ~ 158°F)
Medium temperature: Max, 100°C @ Ambient temperature-20°C ~ 70°C(-4°F ~ 158°F)
Power supply: 18 VDC ~ 30 VDC
Output load current: Max. 50 mA