8. Technical Performance

8.1 Specifications

Scope (optional)
Storage
temperature
Ambient
temperature
Operating
temperature
Power Supply
Current
consumption
Overvoltage
protection
Reverse
protection
Output type
(optional)
Number of
outputs
Switch type
(optional)
Output load
current
Output voltage
drop
Normal type
Water-based media, oil-based media, powder
media, dual-level media (such as oil+water),
fluid with separation layer (such as bubbles)
-40°C ~ 85°C (-40°F ~ 185°F)
-40°C ~ 85°C
(-40°F ~ 185°F)
Continuous: max.100°C
while ambient temp.
-40°C~85°C(-40°F~185°F)
Short time(1hr):
max.150°C
(Mini type: max.135°C)
while ambient temp.
-40°C~60°C(-40°F~140°F)
18 VDC ~ 30 VDC
Max. 50 mA
Class II
Yes
DC PNP/NPN
2 switch outputs
Group 1 output NO, Group 2 output NC
Max. 100 mA
Max. 2.5 VDC
Rear install type
-40°C ~ 80°C
(-40°F ~ 176°F)
-40°C ~ 80°C
(-40°F ~ 176°F)
10
Explosion
proof type
Powder media
-20°C ~ 70°C
(-4°F ~ 158°F)
Max.100°C while
ambient temp.
-20°C ~ 70°C
(-4°F ~ 158°F)
Max. 50 mA