AO2 output
P06.26
filter time

P07 group HMI

Function
Name
code
User
P07.00
password
Function
P07.01
parameter
copy
0–65535
When you set the function code to a non-zero
number, password protection is enabled.
If you set the function code to 00000, the
previous user password is cleared and
password protection is disabled.
After the user password is set and takes
effect, you cannot enter the parameter menu
if you enter an incorrect password. Please
remember your password and save it in a
secure place.
After you exit the function code editing
interface, the password protection function is
enabled
within
protection is enabled, "0.0.0.0.0" is displayed
when you press the PRG/ESC key again to
enter the function code editing interface. You
need to enter the correct user password to
enter the interface.
Note: Restoring the default values may delete
the user password. Exercise caution when
using this function.
The function code determines the manner of
parameters copy.
0: No operation
1: Upload the local function parameter to the
keypad
2: Download the keypad function parameter
to local address (including the motor
parameters)
3: Download the keypad function parameter
Description