P05 Group Input Terminals - Kruger Ecowatt Drive K120 Series Operation Manual

Table of Contents

Advertisement

Ecowatt
®
Drive K120 series
Function
Name
code
Weakening
coefficient
P04.33
in constant
power zone

P05 group Input terminals

Function
Name
code
HDI input
P05.00
type
S1 terminal
P05.01
function
selection
S2
terminal
P05.02
function
selection
S3
terminal
P05.03
function
selection
S4
terminal
P05.04
function
selection
S5
terminal
P05.05
function
selection
The function code is used to adjust the output
voltage of the VFD in SVPWM mode during
flux-weakening.
Note: This parameter is invalid in the
constant torque mode.
Output voltage V
out
b
Setting range of P04.33: 1.00–1.30
0: HDI is high-speed pulse input. See
P05.49–P05.54.
1: HDI is digital input. See P05.09.
0: No function
1: Forward running (FWD)
2: Reverse running (REV)
3: 3-wire running control (SIn)
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
9: External fault input
10: Frequency increase (UP)
11: Frequency decrease (DOWN)
12: Clear frequency increase/decrease setting
13: Switch between A setting and B setting
14: Switch between combination setting and
A setting
15: Switch between combination setting and
B setting
16: Multi-step speed terminal 1
Description
(P04.33-1.00)*Vb
Output frequency f
Description
-62-
Function parameter list
Default
Modify
1.00
Default
Modify
0
1
4
7
0
0