Environmental Specifications

Dimensions (H x D x W)
Environmental Specifications
Environmental Ranges
Operating temperature
5
Storage temperature
Operating relative humidity
Storage relative humidity
Storage altitude
5
Note
When using the Cisco Catalyst 1000 series 8-port and 16-port switches with GLC-BX-U or GLC-BX-D SFP
module, the thermal limitations are as follows:
• Up to 5,000 ft (1524 m), the operation temperature should not exceed 113°F (45°C).
• Up to 10,000 ft (3048 m), the operation temperature should not exceed 104°F (40°C).
Cisco Catalyst 1000 Series 8-Port and 16-Port Switch Hardware Installation Guide
48
Minimum ambient temperature for cold start is 32°F (0°C)
• 10.56 x 7.28 x 1.73 in (C1000-8T-2G-L)
• 10.56 x 7.28 x 1.73 in (C1000-8T-E-2G-L)
• 10.56 x 12.73 x 1.73 in (C1000-8P-2G-L)
• 10.56 x 7.28 x 1.73 in (C1000-8P-E-2G-L)
• 10.56 x 12.73 x 1.73 in (C1000-8FP-2G-L)
• 10.56 x 7.28 x 1.73 in (C1000-8FP-E-2G-L)
• 10.56 x 10.69 x 1.73 in (C1000-16T-2G-L)
• 10.56 x 8.26 x 1.73 in (C1000-16T-E-2G-L)
• 10.56 x 11.69 x 1.73 in (C1000-16P-2G-L)
• 10.56 x 8.26 x 1.73 in (C1000-16P-E-2G-L)
• 10.56 x 12.14 x 1.73 in (C1000-16FP-2G-L)
23 to 122°F (–5 to 50°C) up to 5,000 ft (1524 m)
-13º to 158ºF (-25º to 70ºC) up to 15,000 ft (4572 m)
5% to 90% (noncondensing)
5% to 95% (noncondensing)
Up to 15,000 ft (4572 m)
Technical Specifications