Safety Considerations - Bryant 926SA Installation, Start-Up, Operating, Service And Maintenance Instructions

Single-stage, non-communicating, variable-speed, ecm multipoise, condensing gas furnace
Table of Contents

Advertisement

926SA: Installation, Start-up, Operating, Service and Maintenance Instructions
FURNACE SIZE
CABINET WIDTH
30040V14
36040V17
36060V14
42060V17
48080V17
60080V21
60100V21
66120V24

SAFETY CONSIDERATIONS

WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause carbon monoxide poisoning, explosion, fire, electrical
shock, or other conditions which may cause personal injury or property
damage. Consult a qualified service agency, local gas supplier, or your
distributor or branch for information or assistance. The qualified
service agency must use only factory-authorized and listed kits or
accessories when modifying this product.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
NOTE: ALL DIMENSIONS IN INCH (MM)
Fig. 1 – Dimensional Drawing
A
B
OUTLET WIDTH
14-3/16 (361)
12-1/2 (319)
17-1/2 (445)
15-7/8 (403)
14-3/16 (361)
12-1/2 (319)
17-1/2 (445)
15-7/8 (403)
17-1/2 (445)
15-7/8 (403)
21 (533)
19-3/8 (492)
21 (533)
19-3/8 (492)
24-1/2 (622)
22-7/8 (581)
U.S. ECCN: Not Subject to Regulation (N.S.R.)
C
BOTTOM INLET WIDTH
12-9/16 (322)
16 (406)
12-9/16 (322)
16 (406)
16 (406)
19-1/2 (495)
19-1/2 (495)
23 (584)
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation,
personal injury, death, or property damage.
Furnaces shall NOT be twinned (i.e. tandem or staged operation) unless
approved in factory technical specifications literature for the furnace.
A factory authorized, field-supplied Twinning Kit MUST be used.
Consult furnace pre-sale literature for specific models approved for
twinning and the correct twinning kit. Twinned furnaces must be
installed on both a common supply AND a common return duct system
as shown in the Twinning Kit Installation Instructions. Only two
furnaces can be twinned on a common supply and return duct system
using a factory authorized twinning kit.
3
SD5660-4 REV. -
D
SHIP WT.
LB (KG)
AIR INTAKE
7-1/8 (181)
123 (55.8)
8-3/4 (222)
136 (61.7)
7-1/8 (181)
132 (59.9)
8-3/4 (222)
146 (66.2)
8-3/4 (222)
150 (68)
10-1/2 (267)
161 (73)
10-1/2 (267)
170 (77.1)
12-1/4 (311)
189 (85.6)
WARNING
A210210

Advertisement

Table of Contents
loading

Table of Contents