Bryant 925SA Series Product Data

Bryant 925SA Series Product Data

Preferred series; a series single-stage 4-way multipoise condensing

Advertisement

925SA
PREFERREDt SERIES SINGLE- - STAGE
4- -WAY MULTIPOISE
CONDENSING GAS FURNACE, SERIES A
The 925SA Multipoise SEER Boost Condensing Gas Furnace
features the single- -stage Preferred™ System. The multi- -tap ECM
blower motor is at the heart of the electrical efficiency provided by
this furnace. With an Annual Fuel Utilization Efficiency (AFUE)
of 96.2%, the Preferred single- -stage gas furnace provides added
savings over standard gas furnaces. This Preferred Gas Furnace
features 4- -way multipoise installation flexibility, and is available in
five model sizes. The 925SA can be vented for direct
vent/two- -pipe,
ventilated
applications. A Bryant Preferred Control and Preferred Air
Conditioner or Heat Pump, can be used to form a complete
Preferred Series System. All units meet California Air Quality
Management District emission requirements. All sizes are design
certified in Canada.
STANDARD FEATURES
S Quiet operation. Compare for yourself at HVACpartners.com
S Ideal height 35" (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service
S Preferred Features—match with the Preferred Control for
Product Data
combustion
air,
or
single- -pipe
Preferred System benefits
S Silicon Nitride Perfect Light™ Hot Surface Igniter
S SmartEvap™ technology helps control humidity levels in the
home when used with a compatible humidity control system
S Fan On Plus™ technology allows control of continuous fan
speed from a compatible thermostat
S External Media Filter Cabinet included
S 4- -way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional through- -
the- -cabinet downflow venting capability
S Multi- -tap ECM blower motor, single- -speed inducer motor, and
single- -stage gas valve
S Self- -diagnostics
S Adjustable blower speed for cooling, continuous fan, and
dehumidification
S Aluminized- -steel primary heat exchanger
S Stainless- -steel condensing secondary heat exchanger
S Propane convertible (See Accessory list)
A11264
S Factory- -configured ready for upflow applications
S Fully- -insulated casing including blower section
S Convenient Electronic Air Cleaner and Humidifier connections
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air
S Installation flexibility: sidewall or vertical vent
S Residential installations may be eligible for consumer financing
through the Retail Credit Program

LIMITED WARRANTY*

S 10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
{
Jurisdictions where warranty benefits cannot be conditioned on registra-
tion will receive registered limited warranty benefits.
Use of the AHRI Certified
manufacturer's participation in the program. For
verification of certification for individual products,
CERTIFIED
go to www.ahridirectory.org.
1
Mark indicates a
TM
Always Ask For

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 925SA Series

  • Page 1: Limited Warranty

    4- -way multipoise installation flexibility, and is available in S Installation flexibility: sidewall or vertical vent five model sizes. The 925SA can be vented for direct S Residential installations may be eligible for consumer financing vent/two- -pipe,...
  • Page 2: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 030040 042060 048080 048100 066120 Input High Heat (BTUH) 40,000 60,000 80,000 100,000 120,000 Output High Heat (BTUH) 39,000 58,000 78,000 98,000 117,000 Efficiency AFUE % (ICS) 96.2 96.2 96.2 96.2 96.2 Certified Temperature 40 - 70 40 - 70 40 - 70 40 - 70...
  • Page 3: Furnace Components

    MODEL NUMBER NOMENCLATURE 1 - 2 8 - 10 6 - 7 12 - 13 Family/Tier Base Eff. Major Series Htg. Stages Htg. Cap. Motor Width Clg. Cap. Voltage Minor Series Features 91 - Legacy 0 --- 90 AFUE 92 - Preferred 3 --- 93 AFUE 98 - Evolution 5 --- 95 AFUE...
  • Page 4 Bryant Perfect Air Purifier - 16x25 (406x635mm) GAPAAXBB1625-A08 Bryant Perfect Air Purifier - 20x25 (508x635mm) GAPAAXBB2025-A08 Bryant Perfect Air Purifier Repl. Filter- 16x25 (406x635mm) GAPABBCAR1625-A05 Bryant Perfect Air Purifier Repl. Filter- 20x25 (508x635mm) GAPABBCAR1625-A05 EZ Flex Cabinet 16” (406 mm) EZXCABCC1016-A20 EZ Flex Cabinet 20”...
  • Page 5 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN. W.C.) INPUT RETURN-AIR SPEED BTUH SUPPLY 5(Gry) 1120 1080 1030 4(Yel) 40000 SIDE/BOTTOM 3(Blu) 2(Org) 1(Red) 5(Gry) 1720 1670 1620 1565 1505 1440 1375 1295 1220 1135 4(Yel) 1325 1285...
  • Page 6 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) Insulation 1/2-in. (12.7 mm) Insulation Single Winter Pipe Pipe Diameter-in. (mm) Pipe Diameter-in. (mm) Pipe Diameter-in. (mm) Stage Design Length in...
  • Page 9: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 10 Bryant cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 11: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots (146mm) A11456A DIMENSIONS (IN. / MM) MEDIA FILTER CABINET SHIPPED WITH SIZES 040--- 08, 040--- 12, 060--- 08, 16 (406.4) 17 (432.8)
  • Page 12: Dimensional Drawing

    DIMENSIONAL DRAWING A11447 NOTE: Doors may vary by model. a. For 800 CFM--- 16--- in. (406 mm) round or 14 1/2 x 12--- in. (368 x 305 mm) rectangle. b. For 1200 CFM--- 20--- in. (508 mm) round or 14 1/2 x 19 1/2--- in. (368 x 495 mm) rectangle. c.
  • Page 13: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...
  • Page 14 Catalog No. PDS925SA ---01 E2011 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/11 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents