RESET

Reset
You can reset all settings to the factory settings and restart the software with the reset
function.
> Press the "Reset" button on your remote control for 10 seconds.
The settings are reset to the factory settings.

6.4 Setting the presence detection

Presence is detected via an electronic sensor that controls the automatic activation
of the actuator plate when someone approaches the toilet. For example, if you have a
very small or very large bathroom, you can adjust the automatic presence detection to
the spatial conditions.
The actuator plate A2 differentiates between normal mode, which can be adjusted for
the close and long-distance range and a special mode for small bathrooms, which can
only be adjusted for the close range. The setting of the intermediate range is done
automatically (see 1.3 Presence detection).
To find out how the different ranges are set, press the "Long-distance range" button
or the "Close range" button on your remote control until the status LEDs begin to light
up. Now the status LEDs on the actuator plate show you the range that you are
currently in: red for the close range, yellow for the intermediate range and turquoise
for the long-distance range. When you move towards or away from the actuator plate
you can see at a glance on the LEDs where the boundaries are between the ranges.

Adjusting the normal mode

You can adjust the presence detection to the conditions in your bathroom via the
remote control (see table 7).
> Press the "Long-distance range" or "Close range" preselection button on your
remote control.
The left status LED on the control panel lights up. You now have 4 seconds to change
the setting step by step.
> Press the "Plus" setting button if you want to increase the setting.
> Press the "Minus" setting button if you want to decrease the setting.
The right status LED lights up blue each time you press the button. The setting is
increased/decreased by the corresponding steps.