Hibernation - power standby mode
With this function you can put the device in the power standby mode. This function will be automatically
activated after a predefined period of time of no DMX activity. In standby mode the lamp/LEDs and all motors
will power down if no DMX signal is sent to the fixture for a period of e. g. 15 minutes (can be user defined).
The fixture will automatically reset and return to normal operation once a DMX signal is sendet.
Service setting
The password for this function is „050".
RDM PID
With this function you can call up various submenus via RDM.
This device is RDM ready. RDM stands for "remote device management" and makes remote control of
devices connected to the DMX-bus. ANSI E1.20-2006 by ESTA specifies the RDM standard as an extension
of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM ready and conventional DMX devices can be operated in one DMX line. The RDM protocol sends own
packages in the DMX512 data feed and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the RDM controller being used.
In general, the device supports the following commands and functions via RDM:
DMX-Address
Lamp on/off
PAN reverse
TILT reverse
Reset default
Display reverse
Reset all
User mode
Lamp hours
Head temperature
Software version
Adjust ventilation fans mode
With this function, you can adjust the ventilation fans mode.
• Select "Fans Control" by pressing Up or Down.
• Press Enter to confirm; the display shows "AUTO".
• Press Up or Down to select "LOW", "HIGH" or "AUTO".
• Press the Enter-button to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Display shutt off time
With this function you can shut off the LED display after 1 to 59 minutes.
Display reverse
With this function you can flip the display by 180° for a better view when the fixture is hung from the truss or
a ceiling.
Key lock
With this function you can lock the keys of the Control Board to e.g. prevent menu tampering. If this function
is activated, the keys will be automatically locked in 15 seconds from the last command. In order to
deactivate or temporarily deactivate the keylock function, press the Mode/Esc button for 3 seconds to regain
access to the menu commands.