Hussmann Impact C2-LGE Technical Data Sheet
Hussmann Impact C2-LGE Technical Data Sheet

Hussmann Impact C2-LGE Technical Data Sheet

Hussmann c2-lge: data sheet
Hide thumbs Also See for Impact C2-LGE:

Advertisement

Quick Links

E
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A. 6W Fan Assembly
0058698
Fan Motor, Evaporator
0142780
Fan Blade
embossing toward motor
B. 0311588
Standard Non-adjustable
Defrost Thermostat
C. 0137880
Optional Adjustable
Refrigeration Thermostat
Note: Changed items have been underlined.
Revision C corrects statistical data on Page 3.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
®
Merchandisers
D
B
C
F
Wiring Item #
E
Item Part #
H
EATERS
D.
(1)
NA
0109417
0109417
0109418
(2)
L
B
AMPS AND
ALLASTS
E.
0376409
(3)
0376410
F.
C2-LGE
Technical Data Sheet
P/N 0397201C
NSF
®
February 2006
F
F
A
Description
Wiring Item #
Canopy Anti-Sweat Heater
4 ft
6 ft
8 ft
12 ft
Ballast, Electronic
2 lamps
3 lamps
Fluorescent Lamp
Replace with like fixtures
P/N 0397201C
Certified
(4)
(5)
(6)

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann Impact C2-LGE

  • Page 1 Standard Non-adjustable Defrost Thermostat C. 0137880 Optional Adjustable Refrigeration Thermostat Note: Changed items have been underlined. Revision C corrects statistical data on Page 3. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. ® Wiring Item # Item Part # EATERS 0109417 0109417...
  • Page 2: Plan Views

    Refrigeration Outlet Back of case to center of refrigeration outlet (D) RH end of case to center of refrigeration outlet 2 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Dimensions shown as inches and (mm). (1835) (881) Skid/ External Base Elec.
  • Page 3 (359) (155) (199) (Note:* Optional Accessory Items) NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ® ) Standard #7 requirements. P/N 0397201C HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. (483) (95) (Note*) (305) (765) (406) (Note*)
  • Page 4: Electrical Data

    115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52 4 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 4 ft 6 ft...
  • Page 5: Shelf Lighting

    Purple B Connector Connector WARNING IRCLED NUMBERS ARTS Grayed components in 12 foot models only. = 120V N = Field G EUTRAL HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Fan Wiring Offtime Defrost Defrost Termination Refrigeration Thermostat Thermostat Light Blue Dark Blue...
  • Page 6: Light Circuits

    All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White 6 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. WARNING IRCLED NUMBERS...
  • Page 7: Shelf Configuration

    18 in. deep when positioned at a 0 º angle. P/N 0397201C Maximum Angle 0° 15° 30° 45° 0° HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. C2-LGE Impact Dairy / Delicatessen Precut & Packaged Produce Top Eight (8) Shelf Hole Locations Shelf Size 12 in.
  • Page 8 CANOPY ANTI-SWEAT HEATER The canopy anti-sweat heater location is shown below. Connections are in the Electrical wireway. Canopy Foil-covered Anti-sweat Heater 8 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Ballast Electrical Wireway Anti-Sweat Heater Wires with Purple Markers Screws Screws...

Table of Contents