Visual Inspection
(continued)
V
S
V-710iJ M
alue
erieS
anual
Advancing O-Ring Gate: Adjusting Worn
O-Rings
To adjust worn O-rings on advancing O-ring gate:
1. Turn Off feeder and remove power cord from outlet.
2. Rotate O-rings by grasping advance knob and pushing to-
wards gate cylinder about .125 to .25 in. (3 to 6 mm). NOTE:
O-rings only advance when pushing toward gate cylinder.
Return knob to position away from gate cylinder.
Standard O-Ring Gate: Adjusting Worn
O-Rings
To adjust worn O-rings on standard O-ring gate:
1. Turn Off feeder and remove power cord from outlet.
2. Remove gate assembly from gate plate.
3. Insert a screwdriver in slot on top of gate assembly and rotate
screwdriver clockwise or counter-clockwise 360° so as to
move worn area of O-ring about .125 to .25 in. (3 to 6 mm).
4. Remove screwdriver and repeat for each ring as necessary.
5. Reinstall gate assembly and restore power.
Replacing Worn Angled Wedge (Bar Gate II)
To replace a worn angled wedge:
1. Turn Off feeder and remove power cord from outlet.
2. Remove gate assembly from gate plate.
3. Remove plate on bottom of gate cylinder (two screws).
4. Remove angled wedge.
5. Install new angled wedge. Reinstall plate on bottom of gate
cylinder (two screws).
6. Reinstall gate assembly and restore power.
27