INSTRUCTIONS CONCERNING CONNECTION CABLES.

Wire size range: AWG 12÷30, (solid/stranded) (UL).
Use 60/75°C copper (Cu) conductor only.
We recommend the use of separate power supplies for the safety
module and for other electrical power equipment (electric motors,
inverters, frequency converters) or other sources of disturbance.
Cables used for connections of longer than 50m must have a cross-
section of at least 1mm2 (AWG16).
TERMINAL
SIGNAL
1
24VDC
2
NC
3
NC
4
0VDC
5
OSSD1
6
OSSD2
RESTART_FBK1/
7
STATUS1
RESTART_FBK2/
8
STATUS2
9
OSSD3
10
OSSD4
RESTART_FBK3/
11
STATUS3
RESTART_FBK4/
12
STATUS4
13
OUT_TEST1
14
OUT_TEST2
15
OUT_TEST3
16
OUT_TEST4
17
INPUT1
18
INPUT2
19
INPUT3
20
INPUT4
21
INPUT5
22
INPUT6
23
INPUT7
24
INPUT8
8541220 01 • 18/03/2021 • Rev.0
MOSAIC M1S - MASTER MODULE
M1S module
TYPE
DESCRIPTION
-
24VDC power supply
-
-
-
0VDC power supply
Output Solid State Safety Output 1
Output Solid State Safety Output 2
Feedback/Restart 1
Input/
Output
Programmable signal output
Feedback/Restart 2
Input/
Output
Programmable signal output
Output Solid State Safety Output 3
Output Solid State Safety Output 4
Feedback/Restart 3
Input/
Output
Programmable signal output
Feedback/Restart 4
Input/
Output
Programmable signal output
Output Short circuit detected output
Output Short circuit detected output
Output Short circuit detected output
Output Short circuit detected output
Input
Digital input 1
Input
Digital input 2
Input
Digital input 3
Input
Digital input 4
Input
Digital input 5
Input
Digital input 6
Input
Digital input 7
Input
Digital input 8
-
-
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
Input according to EN 61131-2
OPERATION
-
-
-
-
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
PNP active high
13