Table 5-1. Sna/Sdlc Application Configuration Settings - ADTRAN Express 5210 User Manual

Frame relay service unit
Table of Contents

Advertisement

DTE Port
Protocol
SDLC
Physical Layer
INTERFACE TYPE=EIA-232
Options
BIT RATE=19.2K
TD CLOCK SOURCE=INTERNAL
TRANSMIT IDLE CODE=FLAGS
Protocol
POLL/RESPONSE TIMEOUT=3
Options
MINIMUM POLL TIMER=0
SLOW POLL RATIO=1
DISCONNECT THRESHOLD=10
TRANSMIT DELAY=0
CTS OPTION=FOLLOW RTS
DATA FORMAT=NRZI
Address Table
ENTRY #1
PU ADDRESS=C0
GROUP ADDRESS=0
LLC2 SSAP=04
LLC2 DSAP=04
OUTGOING DLCI=120
Network Port
Physical Layer
LOOP RATE=64K
Options
CLOCK SOURCE=FROM NTWK
Frame Relay
SIGNAL TYPE=ANSI T1.617-D
Options
T391=10
N391=6
N392=3
N393=4
REMOTE FECN = DO NOT NOTIFY REMOTE FECN= DO NOT NOTIFY
61200208L1-1

Table 5-1. SNA/SDLC Application Configuration Settings

HOST 5210
Express 5210 User Manual
Chapter 5. Applications
REMOTE 5210
SDLC
INTERFACE TYPE=EIA-232
BIT RATE=19.2K
TD CLOCK SOURCE=INTERNAL
TRANSMIT IDLE CODE=FLAGS
POLL/RESPONSE TIMEOUT=3
MINIMUM POLL TIMER=0
SLOW POLL RATIO=1
DISCONNECT THRESHOLD=10
TRANSMIT DELAY=0
CTS OPTION=FOLLOW RTS
DATA FORMAT=NRZI
ENTRY #1
PU ADDRESS=C0
GROUP ADDRESS=0
LLC2 SSAP=04
LLC2 DSAP=04
OUTGOING DLCI=17
LOOP RATE=64K
CLOCK SOURCE=FROM NTWK
SIGNAL TYPE=ANSI T1.617-D
T391=10
N391=6
N392=3
N393=4
5-3