Dmx-512 Connection / Connection Between Fixtures - Future light Pro-Head-Spot PLS-15R User Manual

Table of Contents

Advertisement

Available languages

Available languages

DMX-512 connection / connection between fixtures

The wires must not come into contact with each other, otherwise
Please note, the starting address depends upon which controller is being used.
Only use a DMX-cable and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
DMX-output
XLR mounting-socket:
1: Ground
2
1
2: Signal (–)
3
3: Signal (+)
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
the fixtures will not work at all, or will not work properly.
DMX-input
XLR mounting-plug:
1: Ground
2
1
2: Signal (–)
3
3: Signal (+)
46/64
resistor
00072669, Version 1.0

Advertisement

Table of Contents
loading

Table of Contents