confirmation of the operation carried out there will be 1 flash of the Red Led and the output will become 4,0mA. We
suggest performing this operation after the installation or after the change of the cartridge and every 6-12 months
based on the environmental conditions.
Note: This function is not working if mA output is more than 12mA (10% LEL) and/or red Led is already
been switched on. In this case, it will be necessary to recalibrate the unit and/or replacing the "Cartridge"
"CALIBRATION" (Calibration Code: F2, F2, F2, F1, F2, F1): this function allows completely recalibrate the sensor.
Important: please, only using a mixture 20%LEL (0.88%v/v) Methane in Air (20.9% Oxygen)
Warning: to guarantee that no errors of elaboration happen, the rare possibility exists that during the Calibration
the yellow LED switch off every 8 seconds, in this case interrupt the procedure, switch off and witch on the instru-
ment and repeat the Calibration. If condition persists it will be necessary to send the detector to the supplier for the
reparation.
Important note: During Calibration routine the mA output indicates 0mA.
The "Calibration" can be done in clean air only (environment without the presence of flammable or other polluting gas). With
the keys perform the "Calibration Code ". Wait until the Yellow and Green Led switch on fix and the red Led starts to
flash. Insert the TC011 over the sensor holder, adjust the sample gas bottle valve as the flow meter indicates
around 0.3 l/mins
(see
Fig.3). Wait around 3 minutes, then when the Red Led switch on (and while it's SWITCHED ON),
press the key F2 on the instrument and hold it pressed until the Red Led is switched off for at least 2 seconds (if the
Red Led continue to flash, repeat the operation). Then, close the gas cylinder and remove TC011. At this point we can have
two possibilities:
Yellow and Green Led illuminates: the calibration routine has correctly been performed. Wait 8 seconds, until
the instrument automatically restores the normal working conditions. (see "Operational Description > Preheating")
Yellow LED illuminates: the routine has failed. In this case, wait 8 seconds, until the instrument automatically re-
peat Preheating, then repeat the "Calibration" routine without inserting again the code. If condition still persists after the
replacement of the "Cartridge" it will be necessary to send the detector back to the manufacturer for reparation.
"CALIBRATION CHECK" (Cal Check Code: F2, F1, F2, F1): this operation allow to effect a real functional test of
the equipment with gas after the "Calibration" routine, or after the installation. The "Calibration Check" routine should
be done during the periodic maintenances because this is the only method to verify the instrument real functioning.
The "Calibration Check" should be done using sample gas bottles with a mixture 20%LEL (0.88%v/v) Methane in Air.
With the keys perform the "Cal Check Code ". Wait until the Yellow Led starts to flash (the green one remain fix) In-
sert the TC011 over the sensor holder, adjust the sample gas bottle valve as the flow meter indicates around 0.3
Fig.3). Verify with a voltmeter connected to the Test-Point, the value reaches a value between 184 and
l/mins
(see
216mV, [corresponding to 20mA (±1.6) output and the central unit should be display about 20% LEL (±2)]. Note
that the value result is more different, is necessary to recalibrate the sensor (see "Calibration"). Then, close the gas
bottle, remove TC011, press the key F2 to restore the normal working conditions and the mA output will slowly de-
crease up to 4mA.
F
DESCRIPTION
Le SE293K est une sonde à transmetteur 4÷20mA pour gaz et vapeurs combustibles avec capteur catalytique
destinée à être utilisé en systèmes centralisés d'alarme pour l'industrie et le tertiaire. Le détecteur est constitué par
un boîtier antidéflagrant contenant le circuit électronique et les borniers de raccordement, dans le porte capteur,
placé dans la partie inférieure du boîtier, est logée une "cartouche capteur échangeable" contenant l'élément sen-
sible et les données identificatrices et de réglage.
Le TS293K est un transmetteur sur 3 fils avecun signal de sortie S 4÷20 mA avec fond d'échelle à 20% de la LIE
(Limite Inférieure d'Explosivité), du gaz mesuré
et multivoies Tecnocontrol. Sur la carte principale, à l'intèrieur du boîtier se trouvent les touches de codage F1 et
F2 pour les opérations de vérification et calibrage et 3 LED indiquant les conditions de fonctionnement:
Signalisations et commandes:
Led Rouge "ALARM":
Led Vert "ON":
Led Jaune "FAULT":
Touches F1 et F2
MODÈLES
Les données LIE des Gaz sous indiqués sont rapportés à la norme EN 61779-1.
Le TS293KM permet de détecter le méthane (CH
sité relative à l'air est 0,55 et sa LIE, est 4,4%v/v, exprimé en % Volume.
Le TS293KG permet de détecter le GPL. Le GPL est un gaz plus lourd que l'air, formé d'un mélange composé de
20-30% de propane (C
3
2,05 pour le butane; la LIE, est 1,7%v/v pour le propane et 1,4%v/v pour le butane. Les étalonnages pour GPL doi-
vent être exécutés pour gaz butane qui est l'élément le plus présent dans le GPL.
Le TS293KI permet de détecter l'hydrogène (H
trêmement inflammable. Sa densité relative à l'air est 0,07 et sa LIE, est 4%v/v, exprimé en % Volume.
Le TS293KB permet de détecter les vapeurs d'essence, qui constituent un gaz plus lourd de l'air, extrêmement
inflammable. Sa densité relative à l'air est 2,8 et sa LIE, est 1,2%v/v, exprimé en % Volume.
TECNOCONTROL S.r.l. Via Miglioli 47 SEGRATE ( MI )
Istruzione / User's Manual / Manuel d'utilisation
(Tableau
signal d'alarme ALARM (20%LIE)
fonctionnement normal.
capteur en panne ou déconnecté ou saturé ou échu.
pour les opérations de vérification et calibrage
H
) et de 70-80% de butane (C
8
2
3) Il s'utilise en se raccordant sur les centrales d'alarmes mono
gaz naturel). Le méthane est un gaz plus léger que l'air. Sa den-
4
H
). Sa densité relative à l'air est 1,56 pour le Propane et
4
10
) qui est le plus léger gaz existant, il est inodore, sans couleur, ex-
Tel: 02/26 92 28 90 Fax: 02/21 33 734
Pag.6/10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts293kTs293kgTs293kiTs293kb