Installing A Ssd Hard Drive Into A Rear Drive Bay; Removing A Hard Drive From The Rear Drive Bay; Installing A Hard Drive Into A Rear Hard Drive Carrier - Bosch DIVAR IP 7000 Installation Manual

Hide thumbs Also See for DIVAR IP 7000:
Table of Contents

Advertisement

42
en | Maintenance
10.6

Installing a SSD hard drive into a rear drive bay

This chapter describes the removing and installing of SSD hard drives on the rear side of the
chassis.
10.6.1

Removing a hard drive from the rear drive bay

The unit features two hot-swappable hard drives on the rear side which can be removed
without powering down the system.
The hard drives are mounted in hard drive carriers to simplify their installation and removal
from the chassis. These hard drive carriers also help promote proper airflow for the hard drive
bays.
To remove a hard drive from the chassis:
1.
2.
Notice!
Except for short periods of time (swapping hard drives), do not operate the unit with the
hard drives removed from the bays.
10.6.2

Installing a hard drive into a rear hard drive carrier

The hard drives are mounted in hard drive carriers.
To install a hard drive into the rear hard drive carrier:
1.
2.
3.
4.
2016.07 | V2 | DOC
Press the release button to the right of the hard drive carrier. This extends the hard drive
carrier handle.
Use the handle to pull the drive out of the chassis.
Remove the screws securing the dummy drive to the hard drive carrier.
Remove the dummy drive from the hard drive carrier.
Insert a hard drive into the hard drive carrier with the printed circuit board side facing
down and the connector end toward the rear of the carrier.
Align the mounting holes in both, the hard drive carrier and the hard drive.
Note: There are mounting holes in the hard drive carrier marked "SAS" or "SATA" to aid in
correct installation.
Installation Manual