3.14 REMOTE MODE ENGINE SHUTDOWN
To shutdown the excavator, park in a safe location on flat level ground and away from
other equipment and/or traffic lanes.
From Upperstructure Cab:
1. Stop machine by removing pressure from foot pedals.
2. Swing the machine to align upperstructure with undercarriage
3. Lower attachment/boom to ground or stow boom in boom rest. See "Boom Stow
Procedure" on page 3-35.
4. Operate engine at low idle for 3 to 5 minutes. DO NOT rev engine.
5. Turn key to "OFF" position and remove key.
6. Exit excavator maintaining 3-point contact.
7. Chock wheels (if necessary).
MACHINE ROLL-AWAY HAZARD. Lower boom to
ground or boom rest and stop engine before leaving
cab.
80884013