Whisper Power W-SQ25 User Manual page 37

Mobile diesel generating set 230/400v / 50hz digital diesel control
Table of Contents

Advertisement

3
To take the generating set out of the canopy all hose
and cable connections have to be taken off. The set is
fixed to its base by four rubber mountings and can be
loosened by removing the four nuts from the bolts of
these mountings. The easiest way to get the
generator out of its capsule is by lifting the set with the
aid of the lifting eyes
4
Taking the generator set from its mounting, or to
replace a mounting can be done according to the
drawing below (figure 34)
Fig. 34 Exploded view rubber mountings
EN / W-SQ25 for mobile applications / January 2009
5
One can take off the complete alternator housing.
Before the alternator can be taken off all cables and
wiring has to be taken loose first.
6
Reassembling the generating set one should take
care of alignment, cleaning the surfaces between
engine and alternator and tighten the bolts crosswise
and gradually.
7
Use Loctite 577 to seal the fittings, which should first
be cleaned and made free of oil and grease.
8
Test the generating set first outside its capsule and
check very carefully for leakages before putting it
back in its enclosure.