Cleaning the Thermostat

The thermostats's exterior can be cleaned using a damp cloth. Moisten the cloth
with water and wring out prior to wiping the control. Do not use solvents or cleaning
solutions.

Switch Settings

Switches are set to "On"
position from the factory, and
do not require changing for
most applications.
Switch Position Action
SETBACK
The thermostat follows a programmable setback schedule
ON
as a schedule member if available. Requires the installation
of a Timer 033 to use this feature.
1
OFF
The thermostat does not follow a programmable setback
OFF
schedule.
SCENE
The thermostat responds to changes in the scene (system
ON
wide manual overrides). Requires the installation of a User
2
Switch 479 to use this feature.
OFF
OFF
The thermostat does not respond to scenes.
LOCK ACCESS LEVEL
ON
Locked to 'User' access level. Set to Lock when installation
completed.
UNLOCK ACCESS LEVEL
3
Unlock to allow 'User' and "Installer' access level. Set to
Unlock during installation process.
OFF
tekmarNet
(Installer access level).
Not used
ON
4
OFF
Not used
© 2011
D 528 - 12/11
tNt 528
One Stage Heat
For instructions see brochure
Use at least 65°C conductors
No Power
tN2
tN2
Sensor
1
2
3
4
®
reset control must also be set to Unlocked
6 of 24
ON
ON
1 2 3 4
1 2 3 4
1
2
3
4
1
2
3
4