  • Page 2: General Information

    User’s Manual Edition, 2018 2018 Copyright by Prokit’s Industries Co., Ltd. © 1. General Information This digital multimeter is designed and manufactured in compliance with IEC-61010 safety requirements on electronic measuring instruments and hand-held digital multi-meters. It is compliant with IEC-61010 requirements pertaining to CAT IV 600V, CAT.
  • Page 3 * The meter is prohibited from being used in the vicinity of any explosive gas, vapor or dust. * The measurement must be made with correct input terminals and functions and within the allowable measuring range. * To prevent the meter from being damaged, the value to be input shall not exceed the extremes allowed by each measuring range.
  • Page 4: Safety Symbol

    * When appears, the batteries must be replaced immediately. The low level of a battery will result in incorrect reading on the meter, which is likely to bring electric shock or personal injury to the operator. * In measurement, category III voltage and category IV voltage shall not exceed 1000V and 600V respectively.
  • Page 5: Input Protection Measures

    * The designated replacement parts must be used at the moment of maintenance. * The operator must cut off all relevant power supplies before opening the meter. At the same time, the operator must avoid damage to the meter's elements by ensure that he himself doesn't carry any static. * The meter can only be calibrated, repaired and maintained by professionals.
  • Page 6 Either for professionals, factories, schools, enthusiasts or households, it is an ideal multi-functional meter. 2.1 A Schematic Diagram for the Meter Physical appearance ① Non-contact voltage detection area ② LED Light ③ Non-contact voltage indicator ④ LCD screen ⑤ Select key ⑥...
  • Page 7 ② ① ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩...
  • Page 8: Description Of The Symbols On The Display Unit

    2.2 Description of the symbols on the display unit...
  • Page 10: Description Of Functional Keys

    Table.1 Symbols (Continued) V: the unit of volt V, mV mV: Millivolt,1x10 or 0.001 volt. A: mA: Ampere, the unit of current. Milliampere, 1x10 0.001 A, mA, A ampere. Microampere, 1x10 0.000001 ampere. Ohm, the unit of electric resistance. : k : Kilohm, 1000 Ohm , k , M Megaohm, 1,000,000 ohm.
  • Page 11: Description Of Input Socket

    Press the key, the backlight and the illumination indicator will be on; and press the key anther , you will turn off backlight and illumination indicator. If you don't press the key at all, the function will automatically be disenabled in 15 minutes.
  • Page 12: Led Light

    10A positive input terminal (connected to a test lead in red). 2.5 Accessories 1.Operation Manual X 1 copy 2. Test lead X 1 pair 3. K-Type thermocouple X 1 pce 3. Operational guidelines 3.1 Normal operation 3.1.1 Hold mode In the hold mode, the reading can be maintained on the display unit. Changing the measurement function position or pressing the key "Hold"...
  • Page 13 enter the state of dormancy. The meter can be rebooted when the operator presses "Hold" or " " key in the auto power off mode. 3.2 Measurement guidelines 3.2.1 Measurement of AC voltage and DC voltage To avoid any electric shock and/or damage to the meter, do not attempt a voltage measurement if the voltage (valid value) is 1,000V for DC current or 750V for AC current.
  • Page 14: Frequency Measurement

    will display some information. In this situation, press short circuit “V- ” and “COM” terminal to reset the meter to zero. ◼ Within the AC voltage function, press the key "Select" to measure the frequency of the AC voltage source. ◼...
  • Page 15: Electric Resistance Measurement

    3.2.3 Electric resistance measurement To avoid the meter or the measured equipment from damage, do not attempt a resistance measurement unless the operator has already cut off all power sources for the circuit to be measured and fully discharged all high-voltage capacitors. Ohm is the unit of electric resistance ( ).
  • Page 16: Diode Test

    3.2.4 Diode test To avoid the meter or the measured equipment from damage, do not attempt a diode test unless the operator has already cut off all power sources for the circuit to be measured and fully discharged all high-voltage capacitors. Diode test outside the circuit: 1.
  • Page 17: Capacitance Measurement

    3.2.6 Capacitance measurement To avoid the meter or the measured equipment from damage, do not attempt a capacitance measurement unless the operator has already cut off all power sources for the circuit to be measured and fully discharged all high-voltage capacitors.
  • Page 18 have examined the meter's protective tube. In attempting a measurement, you should use the correct input sockets, function positions and measuring ranges. When a test lead is inserted into the current input socket, do not put the other end of the test lead in parallel connection with any circuit. The meter provides DC current measuring ranges as follows: 600.0uA, 60.00mA, 600.0mA and 10.00A;...
  • Page 19: Measuring Temperature

    1: Voltage may still remain in the absence of any indication. The operator shall not rely on non-contact voltage detector to check the presence of voltage. The detection operation may be affected by various factors, including socket design, insulation thickness and type. When the voltage is input into the meter's input terminal, the voltage sensor LED may be on as a result of induced voltage.
  • Page 20 ⚫ Protection of protective tube: mA position: protective tube F 500mA/250V; A position protective tube F 10A/250V ⚫ Rotation rate: approximately 3 revolutions/second ⚫ Display unit: 6000 counts displayed on LCD screen. Automatically display ⚫ the symbol for unit in accordance with measurement function position. Outrange indication: the LCD screen will display "OL".
  • Page 21 ±(0.8% readings +3 digits) 10mV 600V 100mV ±(1% readings +10 digits) 750V Input impedance:10M Maximal input voltage: 1000Vdc or 750Vac valid value Frequency response: 40Hz-1kHz True RMS 4.2.3 Frequency(at AC Positon) Measuring range Resolution Accuracy 10Hz~1KHz 0.001/0.01/0.1 ± (1%Reading +3 digits) Input voltage range: 200mV-750V AC valid value.
  • Page 22 Forward DC current: approximately 1mA; Open-circuit voltage: Diode test approximately 3.2V. The 0-3V 0.001V display unit shows the approximate value of the diode's forward voltage drop. 4.2.6 Overload protection: 600V DC/AC Beeper continuity Measuring Testing Functions Resolution Description range conditions Open-circuit Buzzer sounds , the voltage:...
  • Page 23 4.2.8 Frequency Measuring range Resolution Accuracy 9.999Hz 0.001Hz 99.99Hz 0.01Hz 999.9Hz 0.1Hz 9.999KHz 0.001 KHz ± (1% Reading +3 digits) 99.99KHz 0.01 KHz 999.9KHz 0.1 KHz 9.999MHz 0.001MHz Input voltage range: 200mV-10V ac valid value Overload protection: 600V DC/AC 4.2.9 Duty Measuring range Resolution Accuracy...
  • Page 24: Meter Maintenance

    not be over 10 seconds. The current measurement shall be carried out 1 minute after the completion of previous measurement. 4.2.11 AC current Measuring range Resolution Accuracy 60mA 0.01mA ±(1% Reading + 3 digits) 600mA 0.1mA 10mA ±(2% Reading + 10 digits) Overload protection: Protective tube for mA measuring range (F500mA/250V) ;...
  • Page 25: General Maintenance

    and have read the information on calibration, performance test and maintenance. 5.1 General maintenance To avoid any electric shock or damage to the meter, do attempt to clean the inside of the meter. You must remove the line connecting a test lead to input signals, before opening the case or battery cover.
  • Page 26 2. Disconnect all test leads from the input socket. 3. Use a screwdriver to remove the screw of battery cover. 4. Take off the battery cover. 5. Take out the old batteries carefully and replace with 1 pc 9 V 6F22 new batteries.