Removal Procedure; Removal Procedure Of Indoor Unit - Gree GWH24YE-S6DBA2A Quick Start Manual

Hide thumbs Also See for GWH24YE-S6DBA2A:
Table of Contents

Advertisement

11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Step
1.Remove filter
a.
Open the panel.
b.
Loosen the clasp shown and
then pull the left filter and right filer
outwards to remove them.
2.Remove horizontal louver
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
70
Caution: discharge the refrigerant
completely before removal.
Procedure
Panel
Left filter and right filer
horizontal
louver
Axile bush
Horizontal louver
Service Manual
Location of step motor
Installation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents