Step
7.Remove cold plasma generator
Screws that are locking the cold plasma
generator.Separate the display board
from the evaporator assy.
8.Remove temperature sensor and grounding wire
Cut off the tieline which binding the
temperature sensor and grounding wire
on the evaporator, and then pull out the
indoor tube temperature sensor from the
evaporator.
Remove the screws at the connection
place between grounding wire and
evaporator.
9.Remove shield cover of electric box sub-assy
Loosen the connection clasps between
shield cover of electric box sub-assy and
electric box, and then remove the shield
cover of electric box sub-assy.
10.Remove wiring terminal
Pull out the wiring terminal of motor and
wiring terminal of step motor from the
mainboard.
Note:
When pulling out the wiring terminal,
pay attention to loose the clasp and don't
pull it so hard.
72
Procedure
Service Manual
Cold plasma generator
Screw
Temperature sensor
Grounding wire
Shield cover of electric box sub-assy
Wiring terminal
of motor
Wiring terminal
of step motor