Installing the Hydraulic-System
Filters
1.
Apply a thin coat of hydraulic fluid on the surface
of the rubber seal of each filter.
2.
Turn the filter clockwise until the rubber seal
contacts the filter adapter, then tighten the filter
an additional 3/4 to 1 full turn.
3.
Repeat for the opposite filter.
4.
Install the filter guards over each filter that you
previously removed.
5.
Use the 3 screws to secure the filter guards.
6.
Verify that the vent plugs are removed before
adding the fluid.
7.
Slowly pour the specified fluid through the
expansion reservoir until fluid comes out of 1
of the vent-plug holes.
8.
Install the vent plug.
9.
Torque the plug to 20 N∙m (15 ft-lb).
10.
Continue to add fluid through the expansion
reservoir until fluid comes out of the remaining
vent-plug hole on the second transmission.
11.
Install the opposite vent plug.
12.
Torque the plug to 20 N∙m (15 ft-lb).
13.
Continue to add fluid through the expansion
reservoir until it reaches the F
the expansion reservoir.
14.
Proceed to
Bleeding the Hydraulic System
(page
54).
Important:
Failure to perform the Bleeding
the Hydraulic System procedure after
changing hydraulic filters and fluid can
result in irreparable damage to the transaxle
drive system.