Omron STC-FDR-SW01 User Manual page 29

Factory drive recorder
Table of Contents

Advertisement

Detection difference
Difference area ratio
OK
Cancel
[1]Setting detection area
2)
1)
1) Select setting No. to add area.
2) Move mouse cursor to the image, and set start point (top-left) by left mouse click.
3) Drag the mouse cursor to the end point (bottom-right) and stop clicking.
Please make sure that end point is on bottom-right side of start point.
If [Number] is set to 1 or more in the Advanced setting button, 1) – 3) is done by
number of detection points.
Sets difference value for event occurrence.
(Range: 1 - 255)
This setting can be changed only when [Event
occurrence confirmation] checkbox is not checked.
Setting value set in the Advanced setting window is
initially set, and any changes made in here will be
applied to Advanced setting windows.
If this value is small, events will occur more frequently,
and if this value is large, events will occur less
frequently.
Sets difference area rate inside configured area.
(Range:1 - 100%)
This setting can be changed only when [Event
occurrence confirmation] checkbox is not checked.
Setting value set in the Advanced setting window is
initially set, and any changes made in here will be
applied to Advanced setting windows.
If this value is small, events will occur more frequently,
and if this value is large, events will occur less
frequently.
Saves settings and close this window.
Close this window without saving settings.
3)
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stc-fdr

Table of Contents