Insert Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings VC41LDVINTSC Installation And Operating Instructions Manual

Clean face direct vent fireplace insert
Table of Contents

Advertisement

VC41LDVI/VC41CDVI Gas Fireplace Insert

INSeRT CLeARANCeS

No combustibles (ie: drapes, doors) may be within, or
swing within 36" of the front of the insert.
Side Wall
10" (254 mm)
Minimum
10" (254 mm)
Minimum
Figure 3 -

Mantel Clearances

MANTeL CLeARANCeS
NOTe: The combustible area above the facing must
not protrude more than 3/4" (19 mm) from the facing.
If it does, it is considered a mantel and must meet the
mantel requirements listed in this manual.
8
14"
(356 mm)
11"
(279 mm)
NOTe: Side clearance
to combustibles is 10"
(254 mm) from opening
whether it is side wall or
FP2988
insert clearances
mantel legs.
12" (305 mm)
Maximum Depth
(356 mm)
Fireplace Insert
Opening
Figure 4 -
Mantel Clearances
FP2988

heARTh ReQuIReMeNTS

The insert must be installed on a noncombustible hearth
extending a minimum of 10" (254 mm) from the fireplace
opening (local codes may require a larger hearth). The
hearth must also extend to both sides of the face.
Finish Wall
12" (305 mm)
14"
FP2989
mantel clearance
CLeARANCeS
Noncombustible
Material Required
up to 14" (356
mm) Above Fire-
place Opening
FP2989
20304685

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc41ldviptscVc41cdvintscVc41ldvi

Table of Contents