ED50/ED100/ED250 Owner's Manual Table of Contents Overhead concealed header Table of contents Table of contents ED50/ED100/ED250 door signage General information ED100/ED250 operator configured for full To our customers energy What you should know ED50 operator and ED100/ED250 Distributor information...
Overhead concealed header 1 General information 1.1 Owner's manual. 1.3 Manual storage. This Owner's manual applies to dormakaba This document must be kept in a secure place, and ED50/ED100/ED250 swing door operators packaged accessible for reference as required. in an overhead concealed header (OHC).
Call your local authorized dormakaba USA Inc. distributor for repair. The distributor's AAADM certified technicians are trained to install and service the ED50/ED100/ED250 overhead concealed swing door system using the dormakaba USA, Inc. Installation and Setup Manuals and in accordance with ANSI/BHMA safety standards.
3.1 Distributor information 3.2 ED50 low energy operator 3.1.1 dormakaba USA Inc. distributor information. ED50 operator is available only as a low energy operator Be sure that the dormakaba USA Inc. distributor has (Para. 3.4). provided the following information for each door 3.3 ED100/ED250 operator power...
ED50/ED100/ED250 Owner's Manual Chapter 4 Overhead concealed header 4 AAADM safety information labels 4.1 Safety information label, full energy swing doors (ANSI/BHMA A156.10) 4.1.1 Full energy automatic swing door safety Fig. 4.1.1 Full energy safety Fig. 4.1.2 Annual information label.
ED50/ED100/ED250 Owner's Manual Chapter 5 Overhead concealed header 5 Daily safety check procedure 5.1 Full energy power operated swing door (ANSI/BHMA 156.10) Fig. 5.1.1 One way traffic, overhead mounted safety NOTICE sensor All figures and diagrams are for purposes of...
Page 10
ED50/ED100/ED250 Owner's Manual Chapter 5 Overhead concealed header 5.1.3 Swing door double egress; knowing act switch activation. 1. Double egress doors are commonly activated by 5. Continue through door, the door should: knowing act switch(es). • Start closing after a minimum of five seconds.
4. Inspect door's overall condition. The appropriate signage (Chapter 7) should be present and all hardware should be in good condition. 5. Have door inspected by a dormakaba USA Inc. AAADM certified technician at least annually. WARNING If there are any problems, discontinue door operation immediately and secure the door in a safe manner.
• Rail lengths should be the width of the open door or Call your local dormakaba USA Inc. distributor greater. for repair. Fig. 6.1.1 Guide rails, jamb and floor mounted Fig.
When the door is pushed into the breakout mode, check that the door will not activate. WARNING If there are any problems, discontinue door operation immediately and secure the door in a safe manner. Call your local dormakaba USA Inc. distributor for repair. ED50/ED100/ED250 DL4615-013 09-2021...
Page 14
"ACTIVATE SWITCH TO OPERATE" on side of door having knowing act switch or other knowing act device. 7.2 ED50 operator and ED100/ED250 operator configured for low energy 7.2.1 Overview Fig. 7.2.1 AUTOMATIC CAUTION DOOR decal Signage and warnings are specified in ANSI /BHMA A156.19, American National Standard for...
Page 15
ED50/ED100/ED250 Owner's Manual Chapter 7 Overhead concealed header 7.3 Door signage, full energy power operated single swing doors (ANSI/BHMA 156.10) Fig. 7.3.1 One decal, one way traffic Fig. 7.3.3 One decal, two way traffic Approach side Swing side Approach side...
Page 16
ED50/ED100/ED250 Owner's Manual Chapter 7 Overhead concealed header 7.5 Door signage, full energy power operated double swing doors (ANSI/BHMA 156.10) Fig. 7.5.1 One way traffic, approach side Fig. 7.5.4 One way traffic, swing side DO NOT DO NOT ENTER...
Page 17
ED50/ED100/ED250 Owner's Manual Chapter 7 Overhead concealed header 7.6 Door signage, low energy power operated double swing doors, initiation of door operation (ANSI/BHMA 156.19) Fig. 7.6.1 Knowing act device, approach side Fig. 7.6.3 Knowing act device, swing side AUTOMATIC...
Page 18
ED50/ED100/ED250 Owner's Manual Chapter 7 Overhead concealed header 7.7 Door signage, full energy power operated double egress swing doors (ANSI/BHMA 156.10) Fig. 7.7.1 OHC RH double egress Fig. 7.7.4 OHC LH double egress Swing side Approach side Approach side Swing side Fig.
Page 19
ED50/ED100/ED250 Owner's Manual Chapter 8 Overhead concealed header 8 ED50/100/ED250 header maintenance 8.1 ED50/ED100/ED250 environment and cleaning 8.1.1 ED50/ED100/ED250 environmental Table 8.3.1 Operator environmental requirements requirements. Ambient temperature 5 to 122 °F ED50/ED100/ED250 overhead concealed header assembly is designed to operate under the Fig.
Page 20
USA Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 F: 717-336-2106 www.dormakaba.us...