Flexim FLUXUS ADM 8027 User Manual

Ultrasonic flowmeter for liquids in explosive atmospheres
Table of Contents

Advertisement

Ultrasonic Flowmeter
for Liquids in Explosive Atmospheres
FLUXUS ADM 8027
FLUXUS F801
FLUXUS ADM 8127B
User Manual
UMFLUXUS_F8V4-6-1EN

Advertisement

Table of Contents
loading

Summary of Contents for Flexim FLUXUS ADM 8027

  • Page 1 User Manual UMFLUXUS_F8V4-6-1EN Ultrasonic Flowmeter for Liquids in Explosive Atmospheres FLUXUS ADM 8027 FLUXUS F801 FLUXUS ADM 8127B...
  • Page 2 FLUXUS is a registered trademark of FLEXIM GmbH. FLEXIM GmbH Boxberger Straße 4 12681 Berlin Germany Tel.: +49 (30) 936 67 660 Fax: +49 (30) 936 67 680 E-mail: flexim@flexim.de www.flexim.com User manual for FLUXUS ADM 8027, F801, ADM 8127B UMFLUXUS_F8V4-6-1EN, 2018-10-10 Copyright (©) FLEXIM GmbH 2018...
  • Page 3 FLUXUS ADM 8027, F801, ADM 8127B Die Sprache, in der die Anzeigen auf dem Messumformer erscheinen, kann eingestellt werden (siehe Abschnitt 10.5). The transmitter can be operated in the language of your choice (see section 10.5). Il est possible de sélectionner la langue utilisée par le transmetteur à l'écran (voir section 10.5).
  • Page 4 FLUXUS ADM 8027, F801, ADM 8127B UMFLUXUS_F8V4-6-1EN, 2018-10-10...
  • Page 5: Table Of Contents

    Installation of FLUXUS ADM 8027 ........
  • Page 6 Installation of the Transducers for Mines with FLEXIM Clasps for Mines ......
  • Page 7 Content FLUXUS ADM 8027, F801, ADM 8127B Settings................111 16.1...
  • Page 8 FLUXUS ADM 8027, F801, ADM 8127B Content UMFLUXUS_F8V4-6-1EN, 2018-10-10...
  • Page 9: Introduction

    • unsuitable or insufficient maintenance • repair of FLUXUS by unauthorized personnel FLEXIM assumes no responsibility for injuries to the customer or third persons directly caused by material failure due to unpredictable defects in the product or for any indirect damages.
  • Page 10: Handling

    FLUXUS ADM 8027, F801, ADM 8127B 2 Handling Handling First Inspection The measuring instrument has already been tested thoroughly at the factory. At delivery, proceed to a visual control to make sure that no damage has occurred during transportation. Make sure that the specifications of the delivered measuring instrument correspond to the specifications given on the pur- chase order.
  • Page 11: General Principles

    3 General Principles FLUXUS ADM 8027, F801, ADM 8127B General Principles For the ultrasonic measurement of the flow rate, the flow velocity of the fluid in a pipe is determined. Further physical quantities (e.g., volumetric flow rate, mass flow rate) are derived from the flow velocity and from additional physical quan- tities, if necessary.
  • Page 12 FLUXUS ADM 8027, F801, ADM 8127B 3 General Principles Sound speed c Speed of the propagating sound. The sound speed depends on the mechanical properties of the fluid or the pipe material. In pipe materials and other solid materials, a distinction is made between the longitudinal and transversal sound speed.
  • Page 13 3 General Principles FLUXUS ADM 8027, F801, ADM 8127B transducer (emitter) transducer (receiver) reduction in distance in the transducer α α α pipe wall β β γ flow direction γ of the fluid sound path without flow sound path with flow Fig.
  • Page 14 FLUXUS ADM 8027, F801, ADM 8127B 3 General Principles 3.2.3 Measurement of the Flow Velocity in the NoiseTrek Mode When fluids with a high proportion of gas bubbles or solid particles are measured, the attenuation of the ultrasonic signal increases and can inhibit the propagation of the signal in the fluid. A measurement in the TransitTime mode is not possible anymore.
  • Page 15: Measurement Arrangements

    3 General Principles FLUXUS ADM 8027, F801, ADM 8127B Measurement Arrangements 3.3.1 Terms Diagonal arrangement The transducers are mounted on the opposite sides of the pipe (see Fig. 3.6). Reflection arrangement The transducers are mounted on the same side of the pipe (see Fig. 3.7).
  • Page 16 FLUXUS ADM 8027, F801, ADM 8127B 3 General Principles Sound beam plane The plane containing one, two or more sound paths or beams (see Fig. 3.10). 2 sound paths 2 beams in 1 plane in 1 plane Fig. 3.10: Sound paths and beams in one plane 3.3.2...
  • Page 17: Description Of The Transmitter

    4 Description of the Transmitter FLUXUS ADM 8027, F801, ADM 8127B Description of the Transmitter FLUXUS ADM 8027 The transmitter consists of 2 housings. The command panel is on the front side of the upper housing. The keys are oper- ated by a magnetic pen when the housing is closed.
  • Page 18: Keyboard

    FLUXUS ADM 8027, F801, ADM 8127B 4 Description of the Transmitter Keyboard The keyboard consists of 5 keys. Tab. 4.1: General functions ENTER confirmation of selection or entered value BRK + CLR + ENTER RESET: Press these three keys simultaneously to correct a malfunction. The reset has the same effect as restarting the transmitter.
  • Page 19: Selection Of The Measuring Point

    5 Selection of the Measuring Point FLUXUS ADM 8027, F801, ADM 8127B Selection of the Measuring Point Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). The correct selection of the measuring point is crucial for achieving reliable measurement results and a high measurement accuracy.
  • Page 20 FLUXUS ADM 8027, F801, ADM 8127B 5 Selection of the Measuring Point Observe the notes in the following table: Tab. 5.1: Recommended transducer mounting position horizontal pipe Select a measuring point where the transducers can be mounted on the side of the pipe, allowing the sound waves to propagate in the pipe horizontally.
  • Page 21: Undisturbed Flow Profile

    5 Selection of the Measuring Point FLUXUS ADM 8027, F801, ADM 8127B Undisturbed Flow Profile Some flow elements (elbows, slide valves, valves, control valves, pumps, reducers, diffusers, etc.) distort the flow profile in their vicinity. The axisymmetrical flow profile needed for correct measurement is no longer given. A careful selection of the measuring point helps to reduce the impact of disturbance sources.
  • Page 22 FLUXUS ADM 8027, F801, ADM 8127B 5 Selection of the Measuring Point Tab. 5.2: Recommended distance from disturbance sources; D = nominal pipe diameter at the measuring point, l = recommended distance disturbance source: T piece supply line: l ≥ 50 D return line: l ≥...
  • Page 23: Selection Of The Measurement Arrangement Taking Into Account The Measuring Range And The Measuring Conditions

    5 Selection of the Measuring Point FLUXUS ADM 8027, F801, ADM 8127B Selection of the Measurement Arrangement Taking into Account the Measuring Range and the Measuring Conditions Diagonal arrangement with 1 beam Reflection arrangement with 1 beam • wider flow velocity and sound speed range compared to •...
  • Page 24: Selection Of The Sound Beam Plane Near An Elbow

    FLUXUS ADM 8027, F801, ADM 8127B 5 Selection of the Measuring Point Selection of the Sound Beam Plane near an Elbow With vertical pipe orientation With horizontal pipe flow direction elbow plane elbow plane flow direction • The sound beam plane (see section 3.3.1) has an angle •...
  • Page 25: Installation Of Fluxus Adm 8027

    6 Installation of FLUXUS ADM 8027 FLUXUS ADM 8027, F801, ADM 8127B Installation of FLUXUS ADM 8027 Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). Location • Select the measuring point according to the recommendations in chapter 3 and 5.
  • Page 26 FLUXUS ADM 8027, F801, ADM 8127B 6 Installation of FLUXUS ADM 8027 power supply outputs equipotential bonding terminal upper housing equipotential bonding terminal, lower housing transducers measuring transducers measuring channel B channel A Fig. 6.2: Connections of the Transmitter N/L-...
  • Page 27: Connection Of The Transducers

    6 Installation of FLUXUS ADM 8027 FLUXUS ADM 8027, F801, ADM 8127B Fig. 6.4: Terminal designation of the transmitter (transducers) Connection of the Transducers Note! If transducers are replaced or added, the sensor module also has to be replaced or added (see sec- tion 6.9).
  • Page 28 FLUXUS ADM 8027, F801, ADM 8127B 6 Installation of FLUXUS ADM 8027 Attention! For good high frequency shielding, it is important to ensure good electrical contact between the exter- nal shield and the cap nut (and the housing). • Fix the cable gland by screwing the cap nut onto the basic part (see Fig. 6.5).
  • Page 29 6 Installation of FLUXUS ADM 8027 FLUXUS ADM 8027, F801, ADM 8127B extension cable transducer cable external shield, external shield, brushed back brushed back extension cable compression part cap nut basic part cable gland Fig. 6.7: Connection of the extension and transducer cable to the junction box JB01 •...
  • Page 30 FLUXUS ADM 8027, F801, ADM 8127B 6 Installation of FLUXUS ADM 8027 For the terminal assignment of the transducer cable see Fig. 6.7 and Tab. 6.5. Tab. 6.3: Terminal assignment (transducer cable) terminal connection transducer (core) transducer (shield) transducer (shield)
  • Page 31: Connection Of The Power Supply

    6 Installation of FLUXUS ADM 8027 FLUXUS ADM 8027, F801, ADM 8127B • Insert the extension cable into the junction box. • Prepare the extension cable. • Cut the outer shield to length and brush it back. • Pull the extension cable back until the brushed back external shield is below the shield terminal (see Fig. 6.8). The ex- tension cable has to remain completely insulated up to the shield terminal.
  • Page 32: Connection Of The Outputs

    FLUXUS ADM 8027, F801, ADM 8127B 6 Installation of FLUXUS ADM 8027 cap nut compression part basic part Fig. 6.9: Cable gland FLUXUS ADM 8027, 8027L, 8027LP, FLUXUS ADM 8027C24, 8027LC24, ADM 8027P (transmitter without frequency output): ADM 8027P (transmitter with frequency output):...
  • Page 33 6 Installation of FLUXUS ADM 8027 FLUXUS ADM 8027, F801, ADM 8127B Tab. 6.7: Circuits of the outputs output transmitter external circuit remark internal circuit connection active current loop/ current loop HART < 500 Ω ADM 8027 I1/I2: 2/4 (+)
  • Page 34 FLUXUS ADM 8027, F801, ADM 8127B 6 Installation of FLUXUS ADM 8027 Tab. 6.7: Circuits of the outputs output transmitter external circuit remark internal circuit connection frequency output = 5...30 V (open collector) F1: 2 (+) [kΩ] = U [mA] ADM 8027P = 2...100 mA...
  • Page 35 6 Installation of FLUXUS ADM 8027 FLUXUS ADM 8027, F801, ADM 8127B 6.7.1 Intrinsically Safe Current Output Ex ib The current output may be fed with max. 28.2 V DC/0.76 W. Tab. 7: Circuit of the current output Ex ib...
  • Page 36: Connection Of The Serial Interface

    RS232 adapter cable Fig. 6.1: RS232 interface of FLUXUS ADM 8027 • Insert the RS232 adapter into the socket in such way that the colored lead of the cable is on the marked side of the socket.
  • Page 37: Installation Of Fluxus F801

    7 Installation of FLUXUS F801 FLUXUS ADM 8027, F801, ADM 8127B Installation of FLUXUS F801 Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). Location • Select the measuring point according to the recommendations in chapter 3 and 5.
  • Page 38 FLUXUS ADM 8027, F801, ADM 8127B 7 Installation of FLUXUS F801 equipotential bonding terminal transducer measuring channel A transducer measuring channel B outputs power supply Fig. 7.2: Connections of the Transmitter FLUXUS F801**-A10****-AA, F801**-A10****-AP: FLUXUS F801C24, F801**-A10****-FF: Fig. 7.3: Terminal designation of the transmitter...
  • Page 39: Connection Of The Transducers

    7 Installation of FLUXUS F801 FLUXUS ADM 8027, F801, ADM 8127B Connection of the Transducers Note! If transducers are replaced or added, the sensor module also has to be replaced or added (see sec- tion 7.9). It is recommended to run the cables from the measuring point to the transmitter before connecting the transducers to avoid load on the connectors.
  • Page 40 FLUXUS ADM 8027, F801, ADM 8127B 7 Installation of FLUXUS F801 Tab. 7.1: Terminal assignment (extension cable) terminal connection white or marked cable (core) white or marked cable (shield) brown cable (shield) brown cable (core) 7.5.2 Connection of the Extension Cable to the Junction Box 7.5.2.1...
  • Page 41 7 Installation of FLUXUS F801 FLUXUS ADM 8027, F801, ADM 8127B • Prepare the extension cable. • Cut the external shield and brush it back over the compression part. • Screw the gasket ring side of the basic part into the junction box.
  • Page 42 FLUXUS ADM 8027, F801, ADM 8127B 7 Installation of FLUXUS F801 K L 2 K L 1 shield terminal transducer cable extension cable external shield, external brushed back shield extension cable compression part cap nut basic part cable gland Fig. 7.7: Connection of the extension and transducer cable to the junction box JB01 •...
  • Page 43: Connection Of The Power Supply

    7 Installation of FLUXUS F801 FLUXUS ADM 8027, F801, ADM 8127B For the terminal assignment of the transducer cable see Fig. 7.7 and Tab. 7.5. Tab. 7.5: Terminal assignment (transducer cable) terminal connection transducer (core) transducer (shield) transducer (shield) transducer...
  • Page 44: Connection Of The Outputs

    FLUXUS ADM 8027, F801, ADM 8127B 7 Installation of FLUXUS F801 Tab. 7.6: Connection of the power supply terminal connection terminal connection earth earth neutral + DC Phase 100…240 V AC - DC Connection of the Outputs Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS).
  • Page 45 7 Installation of FLUXUS F801 FLUXUS ADM 8027, F801, ADM 8127B Tab. 7.7: Circuits of the outputs output transmitter external circuit remark internal circuit connection passive current current loop loop/HART = 4...26.4 V F801**-A10****-*P I1/I2: 1/3 (-) > 0.021 A [Ω] + 4 V...
  • Page 46 FLUXUS ADM 8027, F801, ADM 8127B 7 Installation of FLUXUS F801 Tab. 7.7: Circuits of the outputs output transmitter external circuit remark internal circuit connection RS485 120 Ω 14 (A+) termination resistor F801**-A10****-*A F801**-A10****-*P 13 (B-) shield 15 The number, type and connections of the outputs are customized.
  • Page 47: Connection Of The Serial Interface

    7 Installation of FLUXUS F801 FLUXUS ADM 8027, F801, ADM 8127B Connection of the Serial Interface Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). The RS232 interface can only be connected outside of an explosive atmosphere because the housing has to be opened (see Fig.
  • Page 48: Sensor Module (Sensprom)

    FLUXUS ADM 8027, F801, ADM 8127B 7 Installation of FLUXUS F801 Sensor Module (SENSPROM) Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). The sensor module contains important transducer data for the operation of the transmitter with the transducers. It is con- nected to the connector strips above the display of the transmitter.
  • Page 49: Installation Of Fluxus Adm 8127B

    8 Installation of FLUXUS ADM 8127B FLUXUS ADM 8027, F801, ADM 8127B Installation of FLUXUS ADM 8127B Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). Location • Select the measuring point according to the recommendations in chapter 3 and 5.
  • Page 50: Connection Of The Transmitter

    FLUXUS ADM 8027, F801, ADM 8127B 8 Installation of FLUXUS ADM 8127B Connection of the Transmitter Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). Attention! The degree of protection of the transmitter will only be ensured if the cable glands are firmly tightened and the front plate and the housing cover are tightly screwed to the housing.
  • Page 51 8 Installation of FLUXUS ADM 8127B FLUXUS ADM 8027, F801, ADM 8127B It is recommended to run the cables from the measuring point to the transmitter before connecting the transducers to avoid load on the connectors. • Remove the cable gland for mines M16 for the connection of the transducers (see Fig. 8.2).
  • Page 52 FLUXUS ADM 8027, F801, ADM 8127B 8 Installation of FLUXUS ADM 8127B Tab. 8.1: Terminal assignment (transducer cable) terminal connection marked cable (internal shield) marked cable (core) unmarked cable (core) unmarked cable (internal shield) shield marked cable and unmarked shield (external shield)
  • Page 53: Connection Of The Power Supply

    8 Installation of FLUXUS ADM 8127B FLUXUS ADM 8027, F801, ADM 8127B Connection of the Power Supply Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). The external protective earth is connected to the equipotential bonding terminal on the housing of the transmitter (see Fig.
  • Page 54: Connection Of The Outputs

    FLUXUS ADM 8027, F801, ADM 8127B 8 Installation of FLUXUS ADM 8127B Connection of the FLUXUS ADM 8127B Tab. 8.2: Connection of the intrinsically safe power supply terminal connection earth 12 V DC (+), U = 13.2 V 12 V DC (-), U = 13.2 V...
  • Page 55: Sensor Module (Sensprom)

    8 Installation of FLUXUS ADM 8127B FLUXUS ADM 8027, F801, ADM 8127B Tab. 8.4: Circuits of the outputs output transmitter external circuit remark internal circuit connection binary output = 13.2 V (open collector) B1: 14 = 5...12 V [kΩ] = U [mA] = 1...4 mA...
  • Page 56: Mounting Of The Transducers

    • Variofix L: see section 9.3 • Variofix C: see section 9.4 • Transducer for mines and FLEXIM clasp for mines: see section 9.5 Transducer Mounting Fixture Variofix L When measuring in reflection arrangement, the transducer mounting fixtures are mounted on the same side of the pipe (see Fig.
  • Page 57 9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B Fig. 9.4: Transducer mounting fixture Variofix L (diagonal arrangement) Overview of the mounting steps • step 1 disassemble the transducer mounting fixture Variofix L • step 2 fix the clasps to the tension straps •...
  • Page 58 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers 9.3.1 Disassembly of Variofix L • Disassemble the transducer mounting fixture Variofix L (see Fig. 9.6). cover screw rail tension strap clamp Fig. 9.6: Disassembly of Variofix L 9.3.2...
  • Page 59 9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B Fig. 9.9: Ratchet clasp with tension strap 9.3.3 Fixing the Tension Strap to the Pipe One tension strap is fixed to the pipe (see Fig. 9.10). The second tension strap is mounted later.
  • Page 60 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers screw of screw of the clasp the clasp Fig. 9.13: Band clamp clasp with tension strap Fig. 9.14: Quick release clasp with tension strap • Place the tension strap around the pipe and insert it into the clasp (see Fig. 9.14).
  • Page 61 9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B screw of lever the clasp sense of rotation Fig. 9.17: Ratchet clasp with tension strap Attention! To release the screw and the tension strap, press the lever down (see Fig. 9.17).
  • Page 62 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers metal spring tension strap 1 clasp Fig. 9.20: Rail on the pipe Quick release clasp • Insert the tension strap into tension strap clamp 1 and the metal spring (see Fig. 9.22 and Fig. 9.20).
  • Page 63 9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B metal spring tension strap Fig. 9.23: Tension strap with the metal spring and the tension strap clamp Fig. 9.24: Ratchet clasp with tension strap lever screw of the clasp sense of rota- Fig.
  • Page 64 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers 9.3.5 Installation of the transducers in Variofix L • Press the transducers firmly on the transducer clamping fixture in the covers until the transducers are firmly fixed (one transducer in each cover). The transducer cables show in opposite directions (see Fig. 9.27).
  • Page 65: Installation With Variofix C

    9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B Installation with Variofix C When measuring in reflection arrangement, one transducer mounting fixture is mounted on the side of the pipe (see Fig. 9.30). When measuring in diagonal arrangement, two transducer mounting fixtures are mounted on the opposite sides of the pipe (see Fig.
  • Page 66 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers 9.4.1 Disassembly of Variofix C • Disassemble the transducer mounting fixture Variofix C. In order to remove the cover from the rail, bend the outer sides of the cover outwards (see Fig. 9.33).
  • Page 67 9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B tension strap clamp Fig. 9.35: Tension strap with tension strap clamp tension strap clamp metal spring metal spring Fig. 9.36: Tension strap with the metal spring and the tension strap clamp •...
  • Page 68 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers Installation of the rail with the ratchet clasp • Cut the tension strap to length (pipe circumference + at least 120 mm). Note! The edge of the tension strap is very sharp, leading to risk of injury. Remove the burr of the sharp edge.
  • Page 69 9 Mounting of the Transducers FLUXUS ADM 8027, F801, ADM 8127B metal spring ratchet clasp tension strap clamp Fig. 9.41: Tension strap with the metal spring, the ratchet clasp and the tension strap clamp on the pipe Fig. 9.42: Ratchet clasp with tension strap...
  • Page 70 FLUXUS ADM 8027, F801, ADM 8127B 9 Mounting of the Transducers 9.4.3 Installation of the Transducers in Variofix C • Put coupling foil (or some coupling compound for a short-term installation) on the contact surface of the transducers. The coupling foil can be fixed to the contact surface with a small amount of the coupling compound.
  • Page 71: Installation Of The Transducers For Mines With Flexim Clasps For Mines

    Fig. 9.48: Removal of the cover Installation of the Transducers for Mines with FLEXIM Clasps for Mines • Cut the tension straps to the appropriate length. • Insert approx. 20 mm of the tension strap into the slot of part (1) of the clasp (see Fig. 9.49). Bend the end of the tension strap back.
  • Page 72: Start-Up Of The Transmitter

    FLUXUS ADM 8027, F801, ADM 8127B 10 Start-Up of the Transmitter Start-Up of the Transmitter 10.1 Switching on As soon as the transmitter is connected to the power supply, the serial number of the trans- FLEXIM FLUXUS mitter is displayed for a short time.
  • Page 73 10 Start-Up of the Transmitter FLUXUS ADM 8027, F801, ADM 8127B 10.3.2 Program Branches • Program branch Parameter input of the pipe and fluid parameters • Program branch Measuring processing of the steps for the measurement • Program branch Output Options setting of the physical quantity, the unit of measurement and the parameters for the transmission of measured value •...
  • Page 74: Hotcodes

    FLUXUS ADM 8027, F801, ADM 8127B 10 Start-Up of the Transmitter 10.3.3 Navigation If a vertical arrow ↕ is displayed, the menu item contains a scroll list. The current list item is displayed in the lower line. Press key to scroll and select a list item in the lower line. Press Parameter ↕...
  • Page 75: Language Selection

    10 Start-Up of the Transmitter FLUXUS ADM 8027, F801, ADM 8127B 10.5 Language Selection The transmitter can be operated in the languages listed below. The language can be selected with the following HotCodes: Tab. 10.1: Language HotCodes 909031 Dutch 909033...
  • Page 76: Basic Measurement

    FLUXUS ADM 8027, F801, ADM 8127B 11 Basic Measurement Basic Measurement Attention! Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS). The pipe and fluid parameters are entered for the selected measuring point (see chapter 5). The parameter ranges are limited by the technical characteristics of the transducers and the of transmitter.
  • Page 77: Input Of The Fluid Parameters

    11 Basic Measurement FLUXUS ADM 8027, F801, ADM 8127B When the pipe material has been selected, the corresponding sound speed is set automatically. If Other Material is selected, the sound speed has to be entered. Enter the sound speed of the pipe material. Press ENTER.
  • Page 78 FLUXUS ADM 8027, F801, ADM 8127B 11 Basic Measurement If Other Medium is selected, the fluid parameters have to be entered first: • average sound speed of the fluid • range around the average sound speed of the fluid • kinematic viscosity •...
  • Page 79: Other Parameters

    Press ENTER. Note! If standard transducer parameters are used, FLEXIM cannot guarantee for the precision of the mea- sured values. A measurement might even be impossible. If Special Version is selected, enter the 6 transducer parameters specified by the Transd.
  • Page 80: Defining The Number Of Sound Paths

    FLUXUS ADM 8027, F801, ADM 8127B 11 Basic Measurement 11.5 Defining the Number of Sound Paths A value for the number of sound paths corresponding to the connected transducers and the A: Sound Path entered parameters is recommended. Change the value, if necessary. Press ENTER.
  • Page 81 11 Basic Measurement FLUXUS ADM 8027, F801, ADM 8127B 11.6.2 Consistency Check If a wide range for the sound speed has been entered in the program branch Parameter or the exact parameters of the fluid are unknown, a consistency check is recommended.
  • Page 82: Start Of The Measurement

    FLUXUS ADM 8027, F801, ADM 8127B 11 Basic Measurement 11.7 Start of the Measurement The measured values are displayed in the lower line. Press ENTER to return to the fine ad- A:Volume flow justment of the transducer distance (see section 11.6.1).
  • Page 83: Displaying The Measured Values

    12 Displaying the Measured Values FLUXUS ADM 8027, F801, ADM 8127B Displaying the Measured Values The physical quantity is set in the program branch Output Options (see section 12.1). During the measurement, the designation of the physical quantity is displayed in the upper line, the measured value in the lower line.
  • Page 84: Adjustment Of The Display

    FLUXUS ADM 8027, F801, ADM 8127B 12 Displaying the Measured Values All Channels The measured values of all channels (measuring and calculation channels) are displayed. The next active channel is se- lected after min. 1.5 s. Only Calculation Channels Only the measured values of the calculation channels are displayed. The next active calculation channel is displayed after min.
  • Page 85: Status Line

    12 Displaying the Measured Values FLUXUS ADM 8027, F801, ADM 8127B 12.4 Status Line Important data of the ongoing measurement are shown in the status line. The quality and precision of the ongoing mea- surement can be estimated. Press key during the measurement to scroll through the upper line to the status line.
  • Page 86: Advanced Measuring Functions

    FLUXUS ADM 8027, F801, ADM 8127B 13 Advanced Measuring Functions Advanced Measuring Functions 13.1 Command Execution during Measurement Commands that can be executed during a measurement are shown in the upper line. A command begins with →. If pro- grammed, a program code has to be entered (see section 13.12).
  • Page 87 13 Advanced Measuring Functions FLUXUS ADM 8027, F801, ADM 8127B Press key to scroll through the upper line and display the totalizers. A:Volume flow 54.5 m3/h The totalizer value will be displayed in the upper line (here: the volume which has passed 32.5...
  • Page 88: Settings Of The Hybridtrek Mode

    FLUXUS ADM 8027, F801, ADM 8127B 13 Advanced Measuring Functions 13.4 Settings of the HybridTrek Mode The HybridTrek mode combines the TransitTime mode and the NoiseTrek mode. During a measurement in the HybridTrek mode, the transmitter automatically toggles between the TransitTime mode and the NoiseTrek mode depending on the gaseous or solid content in the fluid in order to receive valid measuring values.
  • Page 89: Upper Limit Of The Flow Velocity

    13 Advanced Measuring Functions FLUXUS ADM 8027, F801, ADM 8127B 13.5 Upper Limit of the Flow Velocity Single outliers caused by heavily disturbed surroundings can appear among the measured values of the flow velocity. If the outliers are not ignored, they will affect all derived physical quantities, which will then be unsuitable for the integration (e.g., pulse outputs).
  • Page 90: Uncorrected Flow Velocity

    FLUXUS ADM 8027, F801, ADM 8127B 13 Advanced Measuring Functions 13.7 Uncorrected Flow Velocity For special applications, the uncorrected flow velocity might be of interest. The profile correction for the flow velocity is activated in Special Funct.\SYSTEM settings\Measuring\Flow Velocity. Select normal to display and output the flow velocity with profile correction.
  • Page 91: Calculation Channels

    13 Advanced Measuring Functions FLUXUS ADM 8027, F801, ADM 8127B 13.8.3 Activation/Deactivation of the FastFood Mode If the FastFood mode is enabled and a measurement is started, the normal measuring mode will still be running (i.e. multi- channel measurement with permanent adaptation to the measuring conditions). If the data logger is activated, the mea- sured values will not be stored.
  • Page 92 FLUXUS ADM 8027, F801, ADM 8127B 13 Advanced Measuring Functions Three scroll lists are displayed in the upper line: >CH1< funct ch2↕ • selection of the first measuring channel (ch1) • selection of the calculation function (funct) • selection of the second measuring channel (ch2) Select a scroll list with key The list items are displayed in the lower line.
  • Page 93: Change Of The Limit For The Inner Pipe Diameter

    13 Advanced Measuring Functions FLUXUS ADM 8027, F801, ADM 8127B Select the unit of measurement. Press ENTER. Mass in: ↕ kg/h Two cut-off flow values for each calculation channel can be defined. They are defined in the unit of measurement of the physical quantity selected for the calculation channel.
  • Page 94: Diagnosis With By Means Of The Snap Function

    FLUXUS ADM 8027, F801, ADM 8127B 13 Advanced Measuring Functions 13.11 Diagnosis with the Snap Function With the aid of the snap function it is possible to store measuring parameters which are useful for the evaluation of mea- suring results or for diagnostic purposes.
  • Page 95 13 Advanced Measuring Functions FLUXUS ADM 8027, F801, ADM 8127B 13.12.2 Intervention in the Measurement If a program code is active, the message PROGRAM CODE ACTIVE will be displayed for a few seconds when a key is pressed. The input of a program code is interrupted by pressing key CLR.
  • Page 96: Data Logger And Transmission Of Data

    The transmitter has a data logger in which the measured values are stored during the measurement (see section 14.1). Additionally measured values can be transmitted to a PC via the serial interface (see section14.2). For the connection of the serial interface to the transmitter see section 6.8 (FLUXUS ADM 8027) or section 7.8 (FLUXUS F801). 14.1...
  • Page 97 14 Data Logger and Transmission of Data FLUXUS ADM 8027, F801, ADM 8127B 14.1.3 Settings for the Data Logger Select Special Funct.\SYSTEM settings\Storing. It contains the following menu items: • Start of Storing • ringbuffer • storage mode • storing of the totalizers •...
  • Page 98 FLUXUS ADM 8027, F801, ADM 8127B 14 Data Logger and Transmission of Data Storing of the Signal Amplitude If on is selected and the data logger is activated, the amplitude of the measured signal will Store Amplitude be stored together with the measured values. Press ENTER.
  • Page 99: Transmission Of Data

    14 Data Logger and Transmission of Data FLUXUS ADM 8027, F801, ADM 8127B The type and the serial number of the transmitter is displayed in the upper line. X80X -XXXXXXXX The available data logger memory will be displayed in the lower line (here: 18 327 addition-...
  • Page 100 FLUXUS ADM 8027, F801, ADM 8127B 14 Data Logger and Transmission of Data Select the decimal marker to be used for floating-point numbers (point or comma). Press SER:decimalpoint ENTER. ’.’ >’,’< This setting depends on the setting of the operating system of the PC.
  • Page 101 14 Data Logger and Transmission of Data FLUXUS ADM 8027, F801, ADM 8127B 14.2.5 Online Transmission of Data to a Terminal Program • Start the terminal program. • Enter the transmission parameters into the terminal program (see section 14.2.4). The transmission parameters of the terminal program and the transmitter have to be identical.
  • Page 102 14 Data Logger and Transmission of Data 14.2.7 Offline Transmission of Data with the Program FluxData The measurement data in the data logger are transmitted to a PC via the serial interface RS232 with the FLEXIM program FluxData. Settings in the Program Start the program FluxData V3.0 or higher on the PC.
  • Page 103 14 Data Logger and Transmission of Data FLUXUS ADM 8027, F801, ADM 8127B Stop the Transmission of Data Select the menu: File > Save. Select the series of measured values to be stored. Click OK. Select the path on which the data should be stored and enter the file name.
  • Page 104 FLUXUS ADM 8027, F801, ADM 8127B 14 Data Logger and Transmission of Data The line \DATA is transmitted next followed once by the column titles (see Tab. 14.3) for the corresponding channel. The measured values are transmitted afterwards. Example: \DATA A: \*MEASURE;...
  • Page 105: Libraries

    15 Libraries FLUXUS ADM 8027, F801, ADM 8127B Libraries The internal material database of the transmitter contains parameters for pipe and lining materials as well as for fluids. It can be extended with user defined materials or fluids. User defined materials and fluids will always be displayed in the scroll lists of the program branch Parameter.
  • Page 106: Input Of Material/Fluid Parameters Without The Extended Library

    FLUXUS ADM 8027, F801, ADM 8127B 15 Libraries 15.1.1 Data Retention during Coefficient Memory Partitioning When the coefficient memory is repartitioned, max. 8 data sets of each type can be retained. Example The number of user defined materials is reduced from 5 to 3. The data sets #01 to #03 are retained. The data sets #04 and #05 are deleted.
  • Page 107: Extended Library

    If, however, the process conditions fluctuate strongly and the fluid parameters depend strongly on the temperature (e.g., viscosity of hydraulic oil), polynomials or customized interpolation functions should be used. Contact FLEXIM to find the best solution for the measuring task.
  • Page 108 FLUXUS ADM 8027, F801, ADM 8127B 15 Libraries Customized Interpolation Functions Some dependencies are only approximated insufficiently by polynomials. A number of customized interpolation functions Basics: Y=F(X,Z) are available to interpolate multidimensional dependencies y = f(T, p). For further information contact FLEXIM.
  • Page 109: Deleting A User Defined Material/Fluids

    15 Libraries FLUXUS ADM 8027, F801, ADM 8127B Select yes to store the entered parameters or no to quit the menu item without storing. Save changes Press ENTER. >YES< Fluid Parameter Enter the fluid's: • longitudinal sound speed • kinematic viscosity •...
  • Page 110 FLUXUS ADM 8027, F801, ADM 8127B 15 Libraries Select End of Edit to stop editing. Press ENTER. Material list ↕ >End of Edit Select yes to store all changes of the scroll list or no to quit the menu item without storing.
  • Page 111: Settings

    16 Settings FLUXUS ADM 8027, F801, ADM 8127B Settings 16.1 Time and Date The transmitter has a battery-powered clock. Measured values are automatically stored with the date and time. 16.1.1 Time Select Special Funct.\SYSTEM settings\Set Clock. SYSTEM settings↕ Set Clock Press ENTER.
  • Page 112 FLUXUS ADM 8027, F801, ADM 8127B 16 Settings Enter the pipe circumference. The limits for the pipe circumference are calculated on the Pipe Circumfer. basis of the limits for the outer pipe diameter. During the next scroll through the program branch Parameter, the outer pipe diameter Outer Diameter that corresponds to the entered pipe circumference will be displayed.
  • Page 113 16 Settings FLUXUS ADM 8027, F801, ADM 8127B 16.2.6 Alarm State Indication Select on to display the alarm state during the measurement. SHOW RELAIS STAT For further information on the alarm outputs see section 18.6. >ON< 16.2.7 Units of Measurement...
  • Page 114: Measurement Settings

    FLUXUS ADM 8027, F801, ADM 8127B 16 Settings 16.3 Measurement Settings Select Special Funct.\SYSTEM settings\Measuring. Press ENTER. SYSTEM settings↕ Measuring Note! The settings will be stored at the end of the dialog. If the menu item is quit by pressing key BRK, the changes will not be stored.
  • Page 115: Setting The Contrast

    16 Settings FLUXUS ADM 8027, F801, ADM 8127B 16.4 Setting the Contrast Select Special Funct.\SYSTEM settings\ Miscellaneous to set the contrast of SYSTEM settings↕ the display of the transmitter. Press ENTER. Miscellaneous The contrast of the display is adjusted with the following keys:...
  • Page 116: Superuser-Modus

    FLUXUS ADM 8027, F801, ADM 8127B 17 SuperUser-Modus SuperUser-Modus The SuperUser mode offers the possibility of an advanced analysis of the signal and the measured values as well as the definition of additional parameters adapted to the measuring point, in order to achieve better measuring values or during experimental work.
  • Page 117 17 SuperUser-Modus FLUXUS ADM 8027, F801, ADM 8127B 17.3.1 Profile Bounds Select user if the profile bounds are to be defined. If factory is selected, the default pro- A:Profile bounds file bounds will be used and the menu item Calibration will be displayed (see section factory >USER<...
  • Page 118: Limit Of The Signal Amplification

    FLUXUS ADM 8027, F801, ADM 8127B 17 SuperUser-Modus Example 2: Slope: -1.0 Offset: 0.0 Only the sign of the measured values is changed. Note! The correction data will only be stored when a measurement is started. If the transmitter is switched off without starting a measurement, the entered correction data will be lost.
  • Page 119: Detection Of Long Measurement Failures

    17 SuperUser-Modus FLUXUS ADM 8027, F801, ADM 8127B 17.6 Detection of Long Measurement Failures If there are no valid measured value during a long time interval, new increments of the totalizers will be ignored. The val- ues of the totalizers remain unchanged.
  • Page 120: Display Of The Sum Of The Totalizers

    FLUXUS ADM 8027, F801, ADM 8127B 17 SuperUser-Modus 17.9 Display of the Sum of the Totalizers The sum of the totalizers for the two flow directions can be displayed in the upper line during the measurement. Select Special Funct.\SYSTEM settings\Measuring\Miscellaneous. Press ENTER until the menu item Show ΣQ is displayed.
  • Page 121: Outputs

    18 Outputs FLUXUS ADM 8027, F801, ADM 8127B Outputs If the transmitter is equipped with outputs, they have to be installed and activated before they can be used: • assign a measuring channel (source channel) to the output (if the transmitter has more than one measuring channel) •...
  • Page 122 FLUXUS ADM 8027, F801, ADM 8127B 18 Outputs Tab. 18.1: Configuration of the outputs source item list item output sound speed of the fluid Miscellaneous c-Medium concentration of the fluid Concentration signal amplitude of a measuring channel Signal ratio useful signal to correlated disturbance signal...
  • Page 123 18 Outputs FLUXUS ADM 8027, F801, ADM 8127B Example: source item: volumetric flow rate output: current output output range: 4…20 mA error value delay t (see section 18.2): > 0 The volumetric flow rate cannot be measured during the time interval t ...t...
  • Page 124: Error Value Delay

    FLUXUS ADM 8027, F801, ADM 8127B 18 Outputs Select a list item for the error output. Press ENTER. Error-value ↕ Minimum (4.0mA) If Other value is selected, enter an error value. It has to be within the limits of the output.
  • Page 125: Activation Of An Analog Output

    18 Outputs FLUXUS ADM 8027, F801, ADM 8127B 18.3 Activation of an Analog Output Note! An output can only be activated in the program branch Output Options if it has previously been in- stalled. In the program branch Output Options, select the channel for which an output is to be Output Options ↕...
  • Page 126: Configuration Of A Frequency Output As A Pulse Output

    FLUXUS ADM 8027, F801, ADM 8127B 18 Outputs 18.4 Configuration of a Frequency Output as a Pulse Output A A frequency output sends a signal with a frequency that depends on the volumetric flow rate. The frequency output can be configured in such way that the source item can be totalized by using each period of the output signal as the increment.
  • Page 127: Activation Of A Binary Output As An Alarm Output

    18 Outputs FLUXUS ADM 8027, F801, ADM 8127B Select yes to activate the output. Press ENTER. Pulse Output B1: no >YES< This error message will be displayed if the flow velocity is selected as the physical quantity. Pulse Output The use of the pulse output is not possible in this case because integrating the flow velocity NO COUNTING does not result in a reasonable value.
  • Page 128 FLUXUS ADM 8027, F801, ADM 8127B 18 Outputs Tab. 18.4: Alarm properties alarm property setting description The alarm will switch if the measured value exceeds the upper func (switching condition) limit. The alarm will switch if the measured value falls below the low- er limit.
  • Page 129: Behavior Of The Alarm Outputs

    18 Outputs FLUXUS ADM 8027, F801, ADM 8127B Example 2: Low Limit: -10 m³/h volumetric flow rate = -11 m³/h the measured value is below the limit, the alarm switches volumetric flow rate = -9.9 m³/h the measured value is not below the limit, the alarm does not switch If the switching condition QUANT.
  • Page 130 FLUXUS ADM 8027, F801, ADM 8127B 18 Outputs 18.7.2 Reset and Initialization of the Alarms After an initialization of the transmitter all alarm outputs will be configured as follows: Tab. 18.5: Alarm state after an initialization func NON-HOLD mode NO Cont.
  • Page 131: Deactivation Of The Outputs

    18 Outputs FLUXUS ADM 8027, F801, ADM 8127B 18.7.5 Alarm State Indication Note! There is no visual or acoustic indication of alarm output switching. The alarm state can be displayed after the configuration of the alarm outputs and during the measurement. This function is activated in Special Funct.\SYSTEM settings\Dialogs/Menus.
  • Page 132: Troubleshooting

    A program code has been defined. Press key CLR and enter the program code. The backlight of the display does not work, but all other functions are available The backlight is defective. This problem does not affect the other functions of the display. Send the transmitter to FLEXIM for repair.
  • Page 133: Selection Of The Measuring Point

    Loss of signal during the measurement • If the pipe had been run empty: Was there no measuring signal afterwards? Contact FLEXIM. • Wait briefly until acoustic contact is reestablished. The measurement can be interrupted by a temporarily higher propor- tion of gas bubbles and solids in the fluid.
  • Page 134: Large Deviations Of The Measured Values

    FLUXUS ADM 8027, F801, ADM 8127B 19 Troubleshooting 19.5 Large Deviations of the Measured Values The entered sound speed of the fluid is wrong A wrong sound speed can result in the ultrasonic signal that is reflected directly on the pipe wall being mistaken for the measuring signal that has passed through the fluid.
  • Page 135: A Menu Structure

    A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B Menu Structure INIT-resis- tant Program branch Parameter main menu: selection of the program branch Parameter >PAR< mea opt sf Parameter selection of a measuring channel (A, B) or of a calculation channel (Y, Z) Parameter ↕...
  • Page 136 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant selection of the sound speed range c-Medium range auto: The area around the average sound speed is defined by the transmit- auto >USER< ter. user: The area around the average sound speed has to be entered.
  • Page 137 A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B INIT-resis- tant input of the number of sound paths A: Sound Path display of the transducer distance to be adjusted between the inner edges of Transd. Distance the transducers A:54 mm Reflex...
  • Page 138 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant input of the error value delay, i.e. the time interval after which the error value Error-val. delay is transmitted to the output in case no valid measured values are available This display will only be indicated if Special Funct.\SYSTEM...
  • Page 139 A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B INIT-resis- tant SYSTEM settings\Libraries selection of the displays for the management of the material and fluid scroll SYSTEM settings↕ lists Libraries SYSTEM settings\Libraries\Material list selection of the displays for the arrangement of the material scroll list (pipe Libraries ↕...
  • Page 140 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant selection of the input mode for the measuring point number in the program Meas.Point No.: branch Measuring: (1234) >(↑↓← →)< (1234): digits, point, hyphen (↑↓← →): ASCII editor setting for the display for the input of the transducer distance in the program Transd.
  • Page 141 A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B INIT-resis- tant enabling the NoiseTrek mode Enable NoiseTrek >ON< Selection whether the toggling between the TransitTime mode and the Noise- Auto NoiseTrek ? Trek mode is to be carried out manually or automatically.
  • Page 142 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant input of the cut-off flow for negative measured values -Cut-off Flow range: -12.7...0 cm/s -2.5 cm/s default: -2.5 cm/s This display will only be indicated if Cut-off Flow = sign and Cut-off Flow = user is selected.
  • Page 143 A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B INIT-resis- tant Special Funct.\SYSTEM settings\Measuring\Calibration selection of the measuring channel whose flow parameters are to be defined Calibrat. data ↕ This display will only be indicated if the SuperUser mode is activated.
  • Page 144 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant selection of the sample mode Storage mode • sample: storing and online transmission of the displayed measured value sample >AVERAGE< • average: storing and online transmission of the average of all measured...
  • Page 145 A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B INIT-resis- tant SYSTEM settings\Miscellaneous selection of the display for the setting of the contrast and input of a HotCode SYSTEM settings↕ Miscellaneous setting of the display contrast SETUP DISPLAY ← CONTRAST →...
  • Page 146 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant Install Material selection of the displays for the input of tube and lining materials Special Funct. ↕ Install Material Install Material with Special Funct.\SYSTEM settings\ Libraries\Extended Library = off...
  • Page 147 A Menu Structure FLUXUS ADM 8027, F801, ADM 8127B INIT-resis- tant Install Medium selection of the displays for the input of fluids Special Funct. ↕ Install Medium Install Medium with Special Funct.\SYSTEM settings\ Libraries\Extended Library = off selection whether a user defined fluid is to be edited or deleted Install Medium >EDIT<...
  • Page 148 FLUXUS ADM 8027, F801, ADM 8127B A Menu Structure INIT-resis- tant confirmation that the changes are to be saved Save changes This display will only be indicated if a new fluid has been entered or the pa- >YES< rameters of an existing fluid have been changed.
  • Page 149: B Units Of Measurement

    B Units of Measurement FLUXUS ADM 8027, F801, ADM 8127B Units of Measurement Length/roughness Temperature unit of measurement description unit of measurement description millimeter degree Celsius °C inch degree Fahrenheit inch °F Pressure unit of measurement description bar (absolute) bar(a)
  • Page 150 FLUXUS ADM 8027, F801, ADM 8127B B Units of Measurement Volumetric flow rate Volume (totalized) unit of measurement description unit of measurement cubic meter per day m³/d m³ cubic meter per hour m³/h m³ cubic meter per minute m³/min m³...
  • Page 151 B Units of Measurement FLUXUS ADM 8027, F801, ADM 8127B Mass flow rate Mass (totalized) unit of measurement description unit of measurement metric ton per hour metric ton per day kilogram per hour kg/h kilogram per minute kg/min kilogram per second...
  • Page 152 FLUXUS ADM 8027, F801, ADM 8127B B Units of Measurement Flow Nomogram (Metrical) volumetric flow rate volumetric flow rate V o l u m e n f l u s s V o l u m e n f l u s s...
  • Page 153 B Units of Measurement FLUXUS ADM 8027, F801, ADM 8127B Flow Nomogram (imperial) volumetric flow rate volumetric flow rate V o l u m e n f l u s s V o l u m e n f l u s s...
  • Page 154: C Reference

    The following tables provide assistance for the user. The accuracy of the data depends on the composition, temperature and processing of the material. FLEXIM does not assume liability for any inaccuracies. Sound Speed of Selected Pipe and Lining Materials at 20 °C The values of some of these materials are stored in the internal database of the transmitter.
  • Page 155 C Reference FLUXUS ADM 8027, F801, ADM 8127B Typical Roughnesses of Pipes The values are based on experience and measurements. Material Absolute roughness [mm] drawn pipes of non-ferrous metal, glass, plastics and light 0…0.0015 metal drawn steel pipes 0.01…0.05 fine-planed, polished surface max.
  • Page 156 FLUXUS ADM 8027, F801, ADM 8127B C Reference Fluid (display) Explanation Sound speed Kinematic viscosity Density [m/s] [mm²/s] [g/cm³] ISO VG 32 1 487 78.0 0.8690 ISO VG 32 ISO VG 46 1 487 126.7 0.8730 ISO VG 46 ISO VG 68 1 487 201.8...
  • Page 157 C Reference FLUXUS ADM 8027, F801, ADM 8127B Properties of Water at 1 bar and at Saturation Pressure Fluid temperature Fluid pressure Sound speed Density Specific heat capacity* [°C] [bar] [m/s] [g/cm [kJ/kg/K 1,013 1402.9 999.8 4,219 1,013 1447.3 999.7...
  • Page 158: D Maintenance

    Examination of the O-ring Attention! O-rings on increased safety housings may only be replaced by trained FLEXIM personnel. • Check the O-ring when opening the flameproof enclosure housing (FLUXUS ADM 8027, see Fig. D.1, FLUXUS F801, see Fig. D.2). Flameproof enclosure •...
  • Page 159 D Maintenance FLUXUS ADM 8027, F801, ADM 8127B Tab. D.1 transmitter O-ring item number FLUXUS ADM 8027, upper housing gasket Adalet 120 mm 990735-1 FLUXUS ADM 8027, lower housing gasket Adalet 95 mm 990735-2 FLUXUS F801 O-ring-125x2,5 on request UMFLUXUS_F8V4-6-1EN, 2018-10-10...
  • Page 160: E System Design In Accordance With Ibexu07Atex1061

    FLUXUS ADM 8027, F801, ADM 8127B E System Design in Accordance with IBExU07ATEX1061 System Design in Accordance with IBExU07ATEX1061 UMFLUXUS_F8V4-6-1EN, 2018-10-10...