Installing And Enabling The Peripheral Signaling (Per Sig) Cards; Disabling And Inserting The Fiji Cards; Disabling And Inserting The Conf/Tds Cards, If Necessary - Nortel MER-1002-003 Manual

Add a network group to option 81c cp2-4 with fnf
Table of Contents

Advertisement

Documentation Release Note
Installing and enabling the Peripheral Signaling (Per Sig)
cards

Disabling and inserting the FIJI cards

Disabling and inserting the Conf/TDS cards, if necessary

Nortel Networks
Procedure 9
Installing and enabling Peripheral Signaling cards
1
Install a Per Sig card into slot 4 of each new Network module. Push the
latches forward to lock the card in place.
2
Faceplate enable the cards.
—————————— End of Procedure ——————————
Procedure 10
Disabling and inserting FIJI cards
1
Faceplate disable the FIJI cards.
2
Insert the FIJI cards into slots 2 and 3 of each new Network module.
Do not plug the card into the backplane.
—————————— End of Procedure ——————————
If Conf/TDS cards are used in the system, follow the procedures below.
Procedure 11
Disabling and inserting Conf/TDS cards
1
Faceplate disable the Conf/TDS cards.
2
Insert a Conf/TDS card into each new Network module.
Do not plug the card into the backplane.
—————————— End of Procedure ——————————
11/4/02