Procom Lost River PCILVFD18RT Owner's Operation And Installation Manual page 13

Vent-free gas log heater
Table of Contents

Advertisement

This appliance is factory
preset for propane/LP gas.
No changes are required for
connecting to propane/LP.
Only a qualified installer or service
technician can perform gas selec-
tion and connecting to gas supply.
CAUTION: Two gas line in-
stallations at the same time are
prohibited.
CAUTION: To avoid gas leak-
age for the gas not being used at
the inlet of regulator, a qualified
installer or service technician
must use supplied cap.
You will notice a color coded
plunger on the inside of the regu-
lator. This is normal. When the in-
let connection fitting is inserted
and tightened, this plunger will
be pushed back by the fitting
making all of the adjustments
for the gas being supplied. DO
NOT REMOVE THE PLUNGER.
The regulator will not work.
The inlet regulator is color coded
for identification of the correct
gas type. Blue is for propane (LP
gas) and yellow is for natural gas.
200371-01B
INSTALLATION
GAS SELECTION
Blue Propane/
LP Gas Plunger
Underneath
Dust Cover
Yellow Natural
Gas Plunger
Underneath
Metal Cap
1. Remove blue dust cover.
www.usaprocom.com
Insert Gas Fitting
for Propane/LP Gas
Figure 11 - Gas Regulator
FOR PROPANE/LP GAS
INSTALLATION: BLUE
Blue Dust
Cover
DO NOT REMOVE
Blue Propane/LP Plunger
Install Gas Fitting Here
Insert Gas
Fitting for
Natural Gas