Procom Lost River PCILVFD18RT Owner's Operation And Installation Manual page 10

Vent-free gas log heater
Table of Contents

Advertisement

IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation air
may cause mildew to form too much moisture.
See Air for Combustion and Ventilation, pages
7 and 8.
Before beginning assembly or operation of the
product, make sure all parts are present. If any
part is missing or damaged, do not attempt to
assemble, install or operate the product. Con-
tact customer service for replacement parts.
Before installing heater, make sure you have
the items listed below:
• Hardware package (provided with heater)
• Electric drill with 3/16" drill bit
• Phillips screwdriver
CHECK GAS TYPE
Be sure your gas supply is right for your heat-
er. Otherwise, call dealer where you bought
the heater for proper type heater.
CLEARANCES TO
COMBUSTIBLES
WARNING: Maintain the
minimum clearances. If possible,
provide greater clearances from
floor, ceiling, and adjoining wall.
Measure from outermost point
of heater.
Minimum Fireplace Clearance To
Combustible Materials
Side Wall 16", Ceiling 42", Front 36"
LOG SIZING REQUIREMENTS
Minimum Firebox Size
18" Log Set: Height 20", Depth 13",
Front Width 29", Rear Width 22"
24" Log Set: Height 20", Depth 14",
Front Width 30", Rear Width 23"
Minimum Clearances For Side
Combustible Material, Side Wall
and Ceiling
A. Clearance from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 4.
B. Clearance from the top of the fireplace
opening to the ceiling must not be less
than 42".
10
INSTALLATION
*Minimum 16" from Side Wall
Figure 4 - Minimum Clearance for
Minimum Noncombustible Material
If Not Using Mantel
Note: If using a mantel, proceed to If Using
Mantel. If not using a mantel, follow the infor-
mation below.
You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.)
must be at least 1/2" thick. With sheet metal,
you must have noncombustible material be-
hind it. Noncombustible material must extend
at least 12" up (for all models). See Figure 5
for minimum clearances.
Requirements for Safe Installation
(A) 12" or more: Noncombustible
(A) Less than 8": Noncombustible
material must be extended to at least 8".
See Between 8" and 12", above. If you
cannot extend material, you must operate
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
www.usaprocom.com
Combustible to Wall
Clearances
material OK.
(A) Between 8" and 12":
Install fireplace hood accessory.
heater with flue damper open.
*
Noncombustible
Material Distance
200371-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lost river pcilvfd24rt

Table of Contents