Procom Lost River PCILVFD18RT Owner's Operation And Installation Manual page 12

Vent-free gas log heater
Table of Contents

Advertisement

A. If installing appliance on the floor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
INSTALLING HEATER BASE ASSEMBLY
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
WARNING: If installing in a
sunken fireplace, special care
is needed. You must raise the
fireplace floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting and controls
being damaged. Raise fireplace
floor with noncombustible mate-
rial. Make sure material is secure.
CAUTION: Do not pick up
heater base assembly by burners.
This could damage heater. Only
handle base assembly by grates.
IMPORTANT: Make sure the heater burners
are level. If heater is not level, heater will not
work properly.
12
INSTALLATION
FLOOR CLEARANCES
Combustible
Material
14"
Min.
Noncombustible Material
www.usaprocom.com
B. If combustible materials are less than 14"
to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see Figure 9).
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Installation Items Needed
• hardware package (provided with heater)
• electric drill with 3/16" masonry drill bit
1. Position heater base assembly in fire-
place. Center base assembly left to right
and front to back inside fireplace.
2. Mark screw locations through holes in
mounting brackets (see Figure 10). If
installing in a brick-bottom fireplace, mark
screw locations in mortar joint of bricks.
3. Remove heater base from fireplace.
4. Drill holes at marked locations using 3/16"
drill bit.
5. Attach base assembly to fireplace floor
using two masonry screws provided in
hardware package (see Figure 10).
6. Connect to gas supply. See Connecting
To Gas Supply, page 15.
Figure 10 - Attaching Heater Base to
Fireplace Floor
Hearth
Combustible
Material
5"
Min.
Masonry
Screw
200371-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lost river pcilvfd24rt