AT mode:under this mode all UART data is considered as AT command.
a)
Mode switch, In the transparent transmission mode, after the serial port receives the "+++" frame data, the RX pin receives
b)
any AT command within 3 seconds, and the mode switches to the AT mode. In AT mode, send AT+EXAT<CR><LF> to
switch to transparent transmission mode.

2.2 Network function

a) Short connection: In TCP Client mode, the short connection function is enabled. If there is no data reception in the
serial port or network port within the set time, the network connection will be automatically disconnected. The short
connection function is turned off by default. The connection time can be set from 2 to 255 seconds. When set to 0, the short
connection function is disabled.
b) Registration package: The registration package is closed by default. The user can configure 4 types of registration
packages. You can choose to send the physical address (IMEI code) when connecting, send custom data when connecting,
add the physics before the connection and each packet of data. Custom data is added to the address, connection time, and
data before each packet. The maximum length of the custom registration packet is 40 bytes (when set to HEX format, the
maximum length is 20 bytes).
c) Heartbeat packet: In the idle state of network communication, the heartbeat packet is used for network state
maintenance. The heartbeat period can be set from 0 to 65535 seconds, and the maximum length of the heartbeat packet is
40 bytes (when set to HEX format, the maximum length is 20 bytes). Supports two heartbeat types: network heartbeat and
serial heartbeat. When the network heartbeat is selected, the communication idle time starts, and the heartbeat data packet
is sent to the server according to the configured heartbeat period. Select the serial port heartbeat, start timing
communication idle, and send heartbeat packets to the serial port according to the configured heartbeat period.
Clear the cache: Before the connection to the server is established, the data received by the serial port will be
cached. When the connection with the server is established, you can choose whether to clear the cached data. By default,
the cache is cleared. The maximum size of each Socket in the local cache is 128 bytes, and each Socket buffer is
independent of each other.

2.3 High speed mode

The E840-DTU (4G-02) is designed with a separate high-speed mode. In this mode, both the network and the device can transmit any
packet length data, such as file, picture, and video.
Configure/query the high-speed mode state through the AT+HSPEED command. After the high-speed mode is enabled, the device can
transmit any packet length data at 230400 serial port baud rate and below.
The E840-DTU (4G-02) file transfer process will be demonstrated below:
1. Turn on the device high-speed mode: After the device enters the AT mode, send AT+HSPEED=ON to enable the high-speed mode,
configure the connected server address, and restart the device.