  • Page 1 Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 2: Table Of Contents

    4.4.1 Server IP or Domain Name, Port, TCP or UDP Settings (Socket) ....................21 4.4.2 Custom Registration Package ................................23 4.4.3 Heartbeat Packet ....................................... 25 4.4.4 Heartbeat Packet Time .................................... 26 4.4.5 EBYTE cloud transmission ..................................26 4.4.6 IMEI read ........................................27 4.4.7 SN read ........................................27 4.4.8 Base station positioning value LBS reading ............................27 IMPORTANT NOTICE ............................................28...
  • Page 3: Disclaimer

    Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
  • Page 4: Features

    Support socket connection to remote server, support TCP/UDP;  Adopt Modbus TCP/RTU protocol data processing;  Support connection to Ebyte cloud, command control;  Support 2 working modes, master mode, slave mode, the slave can cascade multiple devices through RS485; ...
  • Page 5: Quick Start

    Refer to subsequent chapters for specific details and instructions. 1.1 Port connection 1.1.1 RS485 connection 1.1.2 Switch input connection 1.1.3 Relay output connection 1.2 Simple to use Wiring: The computer is connected to E831-RTU (6060-4G) via USB to RS485. Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 6: Rs485 Bus Control

    At this time, the device address of the current device can be seen, and the "automatic refresh" √ processing can be performed to control the switch output and read the switch input. Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 7: Network Control

    4G-based remote control. 2.1 Basic parameters Project Norm LTE-FDD:B1/B3/B5/B8 LTE-TDD:B38/B39/B40/B41 WCDMA: B1/B8 Wireless Standard TD-SCDMA: B34/B39 parameters frequency band CDMA: BC0 GSM: 900/1800MHz 172*107*29mm Size(H*W*D) Weight 484.5±5g Operating -20℃~+70℃ Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 8 Data interface RS485:1200~115200bps Network Type Configuration Modbus TCP/ RTU command Software parameters Network protocol Modbus TCP/ RTU Operating mode master mode, slave mode Data transmission TCP/ UDP method 2.2 Dimensions and interface description Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 9 Form dry contact with DIG Switch input Can be paired with DI 1 ground DI 2 Switch input channel Form dry contact with DIG Switch input Can be paired with DI 2 Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 10 For use with relay 1 common open pin NC 2 Relay normally For use with relay 2 common closed pin COM 2 Relay 2 Common For use with Relay 2 NO/NC pins Chengdu Ebyte Electronic Technology Co.,Ltd. E831-RTU(6060-4G) User Manual...
  • Page 11 NO 2 Relay normally For use with relay 2 common open pin NC 3 Relay normally For use with relay 3 common closed pin COM 3 Relay 3 Common For use with relay 3 NO pin/NC pin NO 3 Relay normally For use with relay 3 common open pin...
  • Page 12: Modbus

    3. Modbus 3.1 Register address table Register address table (function code: 0x01H, 0x05H, 0x0FH, 0x03H, 0x06H, 0x10H) register register Register Register register value Support function quantit type address properties range code 00017 (0x0010) Switch read/wri output 0x0000 or 0x01 00018 (0x0011) Switch read/wri 0xFF00(0x05...
  • Page 13: Modbus Address Table

    reporting of switch value Switch 300-65535 40083 (0x0052) read/wri outputtime setting (millisecond) reserve 0x03 Switch value restart 40084 (0x0053) read/wri 0x00 - 0x40 0x06 output state 0x10 Setting reserve 0x03 Server IP or domain read/wri 40100 (0x0063) name (domain 0x06 name in ASCII) 0x10 40122 (0x0079)
  • Page 14: Rs485 Serial Port Baud Rate Code Table

    3.3 RS485 serial port baud rate code table Baud rate code value table 1200 2400 4800 3 (default) 9600 19200 38400 57600 115200 3.4 RS485 serial port check digit value table Check Digit Value Table 0 (default) no verification even parity Odd parity 3.5 Configure parameters through the host computer Select the "parameter setting"...
  • Page 15: Product Features

    4. Product Features 4.1 Working Mode The working mode is divided into master mode and slave mode, which are configured through Modbus register 40081 (0x0050). When the register value is 0, it is the master mode; when the register value is 1, it is the slave mode, and the default slave mode.
  • Page 16: Basic Functions Of Io

    DO6, DO5, DO4, DO3, DO2, DO1 in sequence. Modbus RTU protocol to read digital output: 00 10 00 06 BD CD send Device ModBus address function Switch start address Number of read check code switches code 11 89 receive Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 17 Transport Protocol length Unit ID function code switch address write value 00 01 00 00 00 06 00 11 FF 00 receive Transport Protocol length Unit ID function code switch address write value Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 18: Reading Digital Di Input

    DI6, DI5, DI4, DI3, DI2, DI1 in sequence. Modbus RTU protocol to read digital input: 00 10 00 06 F9 CD send Device ModBus address function Switch start addressNumber read CRC check code code switches 61 8B Receive Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 19: Io Features

    Modbus TCP protocol read pulse count value: 00 01 00 00 00 06 00 30 00 02 Send Transport Protocol ID length Unit ID function initial address number code reads Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 20: Automatic Reporting Of Digital Input Di

    The switch value change upload protocol is listed in the following table, in which the frame header 0xAA and 0xBB are fixed, and the value range of DI1, DI2, DI3, DI4, DI5, DI6 is 0x00, 0x01, 0xFF, among which 0x00 means the digital input is disconnected, 0x01 means the switch input is closed, Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 21: Switch Output Do Time Setting

    If it is a domain name, the corresponding domain name is also converted into the hexadecimal corresponding to ASCII for storage. (Note: The maximum length of the domain name does not exceed 40 ASCII codes) 40101(0x0063) 40101(0x0064) -- 40121(0x0078) Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 22 00 01 Functio number equipment register n code of bytes check ModBus address write value code length address 00 63 00 18 30 1D Receive Device ModBus address function address register length check code code Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 23: Custom Registration Package

    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 The registration package mechanism has 5 modes: Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 24 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 Send Protoc Unit function number register Transp ol ID code of bytes length length addres write value ort ID Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 25: Heartbeat Packet

    00 92 00 16 E0 2A Receive Device ModBus Function address register length check address code code Modbus TCP protocol write registration packet register: Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 26: Heartbeat Packet Time

    4.4.5 EBYTE cloud transmission Ebyte cloud transparent transmission function can be turned on or off. The corresponding design register for this function is 40170 (0x00A9), which supports 0x03, 0x06, 0x10 function codes: When the value of this register is 0x0000, the cloud transparent transmission function is turned off;...
  • Page 27: Imei Read

    40194 (0x00C1) --40213(0x00D4) Base station positioning Base station positioning value value length 00 14 4C 41 43 3A 38 31 32 46 2C 43 49 44 3A 38 30 35 36 42 30 38 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 28: Important Notice

    E78-470LN22S User Manual Important Notice Ebyte reserves the right of final interpretation and modification of all contents in this manual. Due to the continuous improvement of the hardware and software of the product, this manual may be changed without prior notice, and the latest version of the manual shall prevail. Everyone is responsible for protecting the environment: In order to reduce the use of paper, this manual only prints the Chinese part, and the English manual only provides electronic documents.
  • Page 29: Revision History

    龚路 About us Technical support: support@cdebyte.com Documents and RF Setting download link::www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Official hotline: 028-61399028 ext. 821 Web: www.ebyte.com Address: Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China...