Ebyte E840-DTU User Manual page 29

4g/lte serial server
Hide thumbs Also See for E840-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co. Ltd
Format: transmit
transmit:AT+ SMSSEND =<number>,<info> <CR>
return:<CR><LF>+OK<CR><LF>
Parameter:
Number :receiver's phone number
info: transmitted content(English or number)
AT+ SMSINFO
Function:
Format: transmit
transmit:AT+ SMSINFO =<Info> <CR>
return:<CR><LF>+OK<CR><LF>
Inquire
transmit:AT+ SMSINFO <CR>
return:<CR><LF>+OK=<info> <CR>
Parameter:
Info :remote SMS configuration identifier ID
AT+MODBUS
Function:
Format: configure
transmit:AT+ MODBUS =<state> <CR>
return:<CR><LF>+OK<CR><LF>
inquire
transmit:AT+ MODBUS <CR>
return:<CR><LF>+OK=<state> <CR><LF>
Parameter: state
ON
OFF
AT+MTCPID
Function:
Format: configure
transmit:AT+ MTCPID =<id> <CR>
return:<CR><LF>+OK<CR><LF>
inquire
transmit:AT+ MTCPID <CR>
return:<CR><LF>+OK=<id> <CR><LF>
Parameter: id (0~65535 )2 bytes
Remark: when ID is 0, any modbusTCP received will switch to corresponding RTU protocol, otherwise, only when
id is matched can it switch
AT+RSTIME
Function:
Format:
transmit:AT+ RSTIME =<value> <CR>
return:<CR><LF>+OK<CR><LF>
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co. LTD.
configure/inquire SMS configuration identifier ID
configure/ inquire if Modbus RTU/TCP switch function is enabled
Modbus RTU/TCP switch is on
Modbus RTU/TCP switch is off
configure/ inquire Modbus RTU/TCP event identifier
configure/ inquire server response overtime
configure
E840-DTU(4G-02)User Manual