SECTION 7: SPECIFICATIONS AND OPERATING DATA
Item
Nominal Media Volume, Ft3
Salt Dosage, Lbs.
Salt Efficient Setting
Factory Setting
Maximum Setting
Softening Capacity, grains
At Salt Efficient Setting
At Factory Salt Setting
At Maximum Salt Setting
Salt Efficiency, grains per lb. of salt
At Salt Efficient Setting
Flow Rate At 15 psi Pressure Loss
Pressure Loss, psi At Service Flow
Regeneration Flow Rates, gpm
Backwash
Brine Draw @ 50 psi
Slow Rinse @ 50 psi
Rapid Rinse
Brine Refill
Approximate Water Used (at
Factory Setting)
Regeneration Duration, minutes a (at Factory Setting)
1st Backwash
Brine Draw/Rinse
2nd Backwash
Rapid Rinse
Brine Refill
Approximate Total Time
Inlet/Outlet Size
Media tank Dia. x Ht., in.
Overall D & H w/Valve, in.
Width (Including Brine Tank)
Depth
Height (Including Valve)
Brine Tank, W x D x H, in.
Salt settings below 6# require removal of the salt grid
Salt settings above 24# require optional 18 x 33 brine tank
Brine Tank Capacity
Without Salt Grid Leg Extensions
With Salt Grid Leg Extensions
(required on salt settings above
18 #)
Approximate Shipping Wt.
These softeners conform to NSF/ANSI Standard 44 for specific performance claims. When set at the Salt Efficient setting, these softeners meet or exceed
Std. 44 requirement for salt efficiency. Efficiency claim is only valid at the Salt Efficient Setting.
NOTES: For satisfactory performance, indicated flow rates and duration should not be exceeded. Flow rates specified are adequate for normal residential
applications. Do not use Service Flow Rate if treated water is to supply a geothermal heat pump, swimming pool, etc. (contact your Dealer/Installer before
selecting equipment). Service flow rates have been tested against NSF Standard 44.
3MWTS100
1.0
4
6
16
16,300
21,600
29,000
4,078
7.9
4
1.7
0.18
0.27
1.7
0.5
44
6
45
3
3
3'51"
61
1" NPT
8 x 44
33
15
53
15 x 15 x 34
180
N/A
97
3MWTS150
1.5
6
9
16
24,200
32,000
43,000
4,026
11.1
5
2.7
0.26
0.34
2.7
0.5
77
6
45
3
3
3'51"
63
1"NPT
10 x 44
35
15
53
15 x 15 x 34
180
135
125
3MWTS Series Water Softeners – Installation Instructions | 19
3MWTS200
2.0
8
12
24
34,100
45,000
56,800
4,260
9.6
5
2.7
0.26
0.36
2.7
0.5
78
6
45
3
3
7'52"
65
1" NPT
10 x 54
35
15
63
15 x 15 x 34
180
135
154

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3mwts1003mwts1503mwts200