SECTION 3: CONTROL VALVE PROGRAMMING AND REGENERATION
Installer Display Settings
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
RETURN TO
NORMAL MODE
10 | 3MWTS Series Water Softeners – Installation Instructions
STEP 1:
Press SET CLOCK. Push
or
to change hour (AM/PM). Press NEXT then
change minutes. Press NEXT to lock time in.
STEP 2:
Press NEXT and
simultaneously for 3 seconds.
STEP 3:
Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per
gallon using the
or
buttons. The default is 20 with value ranging from 1 to 150 in 1
grain increments.
NOTE: The grains per gallon can be increased if soluble iron needs to be reduced. Press
NEXT to go to Step 3. Press REGEN to exit Installer Display Settings.
STEP 4:
Day Override: Day Override sets the number of days between regenerations and sets the
maximum number of days between regenerations. If value is set as a number (allowable
range from 1 to 28) a regeneration initiation will be called for on that day even if sufficient
number of gallons were not used to call for a regeneration. Set Day Override using
buttons.
- Number of days between regeneration (1 to 28); or "OFF".
Press NEXT to go to Step 4. Press REGEN to return to previous step.
STEP 5:
Next Regeneration Time (hour): Set the hour of day for regeneration using
AM/PM toggles after 12. The default time is 2:00 a.m. Press NEXT to go to Step 5. Press
REGEN to return to previous step.
STEP 6:
Next Regeneration Time (minutes): Set the minutes of day for regeneration using
buttons. Press NEXT to exit Installer Display Settings. Press REGEN to return to previous
step.
To initiate a manual regeneration immediately, press and hold the "REGEN" button for
three seconds.
The system will begin to regeneration immediately. The control valve may be stepped
through the various regeneration cycles by pressing the "REGEN" button.
Power Lost
If an outage of eight hours or more occurs, the time of day will flash on and off which
indicated the time of day should be reset. The system will remember the rest.
Error Message
If the word "error" and a number are alternately flashing on the display contact our
Technical Service at 1300 345 837 for help. This indicates that the valve was not
able to function properly.