Summary of Contents for Power Electronics SE-4LH15

  • Page 1 OWER ELECTRONICS SE-4LH15 AUTOMATIC VOLTAGE REGULATOR USER MANUAL...
  • Page 2 OWER ELECTRONICS SE-4LH15 AUTOMATIC VOLTAGE REGULATOR...
  • Page 3 OWER ELECTRONICS SE-4LH15 POWER TRANSFORMER AUTOMATIC VOLTAGE REGULATOR...
  • Page 4 180mm SE - 4LH15 220mm 201mm HEIGHT 60mm 157mm 180mm POWER TRANSFORMER FOR SE-4LH15 145mm 125mm 1.5 KVA 15Kg HEIGHT 160mm 130mm...
  • Page 5 SE-4LH15 AR P N A S E AT N OUTPUT INPUT CURRENT REQ. CONTINUOUS PHASE ON Y E C. IE D O NEUTRA NO USE AUTO ATIC RE U ATION QUADRATURE DROOP OPER.TE P OR PARA ED OPERATION AD USTA...
  • Page 6 380 - 440 V BUS BAR MODEL SE-4LH15 AUTOMATIC FLASH 50 - 60 Hz COMPATIBILITY. UNDER FREQUENCY PROTECTION. P/F COMPENSATED IN PARALLEL OPERATION. SE-4LH15 CABLE CHECKER IN PARALLEL OPERATION. WRONG PHASE SEQUENCE INDICATOR. REGULATION +/- 0.5% OPERATIONAL TEMPERATURE 80 C MAX...
  • Page 7 ELECTRONICS INSTRUCTIONS TO INSTALLING AND ADJUSTING THE AVR MODELS: SE-4LH15 THREE PHASE CONNECTION & WRONG PHASE SEQUENCE INDICATOR 1. The right suggestion of the phases is a must for the normal function of the AVR. If the bars are marked...
  • Page 8 Powerele@gmail.com ELECTRONICS INSTRUCTIONS TO INSTALLING AND ADJUSTING THE AVR MODELS: SE-4LH15 U/F - Under Frequency Protection. It protects the generator from over-excitation current due to lower engine revs. To adjusting the U/F trimmer proceed as follows: UNDER FREQ PROTECTION The AVR comes with pre-configured Under frequency protection.
  • Page 9 ELECTRONICS INSTRUCTIONS TO INSTALLING AND ADJUSTING THE AVR MODELS: SE-4LH15 ΤΡΙΦΑΣΙΚΗ ΣΥΝΔΕΣΗ & ΣΥΣΤΗΜΑ ΕΛΕΓΧΟΥ ΔΙΑΔΟΧΗΣ ΦΑΣΕΩΣ 1. Η σωστή διαδοχή των φάσεων είναι απαραίτητη προϋπόθεση για την ομαλή λειτουργία του AVR. Αν υπάρχει σήμανση επί των μπαρών (R,S,T) ή (U,V,W) ακολουθούμε...
  • Page 10 ΠΡΑΣΙΝΟ LED ΕΛΕΓΧΟΥ ΣΥΝΔΕΣΗΣ Το πράσινο led είναι ένα εξελιγμένο σύστημα αυτοελέγχου, το οποίο έχει στόχο να βοηθήσει τον τεχνίτη για την σωστή καλωδίωση της νέας εγκατάστασης. Το σύστημα αυτό είναι αποκλειστική πατέντα της POWER ELECTRONICS παγκοσμίως. Το πράσινο led θα ανάψει μόνο* στην...