Manual Flushing
Approach the supplied special magnetic stick (flushing control
stick) to the left part of the sensor lens. The system is now at
a manual status and the indicator will flash every 1 seconds.
Approach the flushing control stick to the window, it ll start to
flush; approach again, stopping flushing. This status will last
for 8 minutes until it turns to the normal working status. (The
flushing, if any, will be terminated when this status ends).
Notice:
The longest flushing time is 30 seconds once. If the
flushing control stick keeps near to the sensing
window, the manual status will be terminated
automatically and reassume the normal working status.

MAINTENANCE

Urinal Repair
When repairing, you don t have to dismount the sensor. Cover
the sensing window with tape and work with ease.
Notice
:
'
Don t use very adhesive tape in case the scar will be
hard to remove.
Clean the Filter Screen
If the flushing volume reclines sharply after installation or
used for a long time with no cause from water pressure, the
filter may need a wash. Turn off the fixed cap with filter-key,
take out the filter, clean with a brush and reinstall it.
Notice:
Turn off the water supply or tighten the adjusting bolt
before cleaning.