Kohler Bardon K-8787T-C01 Installation Instructions Manual

Kohler Bardon K-8787T-C01 Installation Instructions Manual

Touchless urinal sensor (water saving)

Advertisement

·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
consumer
.
RECOMMENDED TOOLS AND MATERIALS
RECOMMENDED TOOLS AND MATERIALS
·
Open end/adjustable wrenches
·
Tape measure
·
Basin wrench
·
Pipe wrench
·
Square
·
Level
·
Pliers
·
Socket wrench with sockets
·
Screw driver
·
Seal tape
·
Connection wire
·
Wire cutter
·
Insulation tape
·
Bushing
SENSOR SPECIFICATION
SENSOR SPECIFICATION
8787T-C01(DC)
Model
8787T-C03(AC)
"
4 AA size alkaline batteries
(8787T-C01)
Power
220V AC 50/60Hz(8787T-C03)
Water pressure 0.3 MPa: about 2~4L
Liter per flushing
(Automatic adjustment)
Water pressure 0.1MPa no more than 3L
Temperature
Environmental temperature: 1 to 60
Starting pressure
0.05~0.7MPa
80cm away from sensing window
Sensing distance
(adjustable)
Testing time
About 2 seconds (or set to 5 seconds)
Note: The sensing distance in the table is measured with a
2
30 30cm white board as the reflecting surface.
1020018-T01-C
please leave instructions for the
"
TOUCHLESS URINAL SENSOR (WATER SAVING)
·
·
·
·
/
·
·
·
·
·
·
·
·
·
·
·
·
·
8787T-C01(
8787T-C03(
4 5
(8787T-C01)
220V AC 50/60Hz(8787T-C03)
(
0.05~0.7MPa
(
18
E
201206
-1-
BARDON
INSTALLATION INSTRUCTIONS
K-8787T-C01(DC/
K-8787T-C03(AC/
)
)
(AA 4)
0.3 MPa
2~4L
)
0.1MPa
3L
: 1 ~60
80cm
)
2
(
5 )
2
30
30cm
Copyright Kohler China Ltd., 2007
)
)
-
, 2007

Advertisement

Table of Contents
loading

Summary of Contents for Kohler Bardon K-8787T-C01

  • Page 1 · · All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. ·...
  • Page 2: Product Page

    PRODUCT PAGE 1020023 Stop Valve Assy. Center Unit Adjusting Bolt "O" Ring 1021431 "O" Pertain 2 Inlet Connenction 16305T-NA 8787T-C03 Use only 8787T-C03 Spring Connection "O" Ring Small "O" Ring "O" "O" Connector Adjustment Nut Plug In 1020011 1019269 Angles Bracket Screw(4 Pcs) 3x8 (4 ) 3x8...
  • Page 3: Installation

    ROUGHING-IN UNIT: mm K-4960T-ET K-4960T-ER R1/2 R1/2 1/2" " 3/4 SPUD 320 40 320 40 2 N.P.S. TAP " " 2 N.P.S. TAP Notice: a. The dimensions above are just for reference. b. The connection take between the outlet connection and urinal is not supplied in this package.
  • Page 4 2. Remove the dust-proof covers from the valve and install the inlet/outlet connections. The outlet connector shall face ater Supply( ecommended Inner away from the wall and at the center of the urinal. Place the Diameter Is More Than 20mm) flushing valve box into the slot, adjust its level and square 20mm) with battens.
  • Page 5 Connect 220V AC . When installing the AC power unit in cassette, please 220V layout the bushing according to Fig. #3, and thread the Bushing wire through the bushing. Fig. #3: Connection sketch AC power unit install in cassette. CAUTION: One AC power unit can supply two sensors at most.
  • Page 6 . Connect the control box with power on(see step 5) with solenoid valve, and check the leakage by manual flushing for several times. Once it is confirmed that there is no leakage, place the mold sheath onto the valve box and apply slurry into the crevice around the valve box and Tiles smooth the surface.
  • Page 7 ¢ Notice: a. Don t mistake the polar of the batteries and ¢ don t mix new and used batteries together. When no enough power, the indicator will flash continuously (20 times at most). When out of power, the indicator will flash every 2 seconds and the sensor will not work until new batteries are supplied.
  • Page 8 Deodorizing Flushing ¢ The urinal will take a big flush automatically when it s used 3 or 4 times in 2 minutes. Water-saving Flushing Flushing volume will be controlled automatically according to the frequency of using and the amount of urine to achieve the best water-saving effects while living up to sanitary standards at the same time.
  • Page 9: Maintenance

    Flushing Volume Water pressure 0.3MPa: The automatic flushing volume is 2 to 4 liters. Adjust when smaller volume is required. Remove the sensor cover when adjusting. Turn the adjusting bolt to a proper place. Adjusting Bolt 0.3MPa 2-4L MAINTENANCE Urinal Repair ¢...
  • Page 10: Troubleshooting

    TROUBLESHOOTING Please make following checks before repair: Symptoms Probable causes Corrective action No power or mistake connected Check the power connect No flushing 2. There is an object 2. Remove the object (Indicator not flashing) within the sensing distance or reduce the sensing distance 3.
  • Page 11: Important Consumer Information

    IMPORTANT CONSUMER INFORMATION Consumer Responsibilities 1. Do not attack the sensor. 2. Do not directly flush the sensor with water. The sensor is an electronic instrument. 3. Do not let sunlight or other light source enter or be reflected into Sensor Window. 4.

This manual is also suitable for:

Bardon k-8787t-c03

Table of Contents