Installing The Ductwork And Grilles; Recommended Insulated Flexible Ductwork Sizing Chart - Wine Guardian D088V Installation, Operation And Maintenance Manual

Ducted and ducted vertica wine cellar cooling systems
Table of Contents

Advertisement

Installing the Ductwork and Grilles

Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only
insulated ductwork to minimize cooling loses, prevent sweating, and to reduce noise.
Use ductwork on the condenser section to redirect or absorb sound, to bring in outside air to the unit
inlet, and/or to exhaust the hot air out of the ambient space.
NOTE:
Do not exceed a total of 25 feet for combined supply and return duct work

Recommended Insulated Flexible Ductwork Sizing Chart

For 60Hz models
Evaporator (cooling) Coil
Model#
8"
D025
10"
D050
10"
D088
12"
D200
D050V
10"
D088V
10"
For 50Hz models
Model
Inlet
WG40
200
WG75
250
WG100
250
WG175
300
Notes:
1. The above referenced 60 Hz sizes are internal diameter in inches and the 50Hz are
in millimeters (mm)
2. If a single supply is used out of the unit but then splits into two ducts, the size above
that is recommended for double is used after the
Inlet
Outlet
(Return
(supply
Air)
air)
Single
Double
8"
10"
10"
12"
10"
10"
10"
Evaporator Coil
Single
Double
Outlet
Outlet
200
150
250
200
250
200
300
250
Part No. 15H0127-00
Condenser (heat rejection) Coil
6"
8"
8"
10"
8"
10"
12"
8"
10"
8"
10"
Condenser Coil
Single
Outlet
Inlet
200
200
250
250
250
250
300
300
split.
Inlet
Outlet
Single
Double
8"
6"
10"
8"
10"
8"
12"
10"
10"
8"
10"
8"
Double
Outlet
150
200
200
250
49