Pulsar MSR 2012 Manual

Pulsar MSR 2012 Manual

Buffer, switch mode power supply module with technical output fac

Advertisement

Quick Links

MSR 2012
v.1.0
MSR 13,8V/2A
Buffer, switch mode power supply module
with technical output FAC.
EN**
Edition: 3 from 21.11.2016
Supersedes the edition: 2 from 11.05.2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSR 2012 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar MSR 2012

  • Page 1 MSR 2012 v.1.0 MSR 13,8V/2A Buffer, switch mode power supply module with technical output FAC. EN** Edition: 3 from 21.11.2016 Supersedes the edition: 2 from 11.05.2015...
  • Page 2: Table Of Contents

    MSR2012 Features:  DC 13,8V/2A uninterruptible power supply  LED indication  high efficiency 83%  FAC technical output indicating AC power loss  low voltage ripple  protections:  battery charging and maintenance control  SCP short-circuit protection ...
  • Page 3: Description Of Components And Connectors

    MSR2012 1.3. Description of components and connectors PSU module. Table 1. Elements of the PSU module pcb (fig. 2). Element no. Description potentiometer, DC adjustment fuse in the battery circuit Connectors: +BAT - DC supply output of the battery +AUX - DC supply output (+AUX= +U, -AUX=GND) FAC - AC absence technical output –...
  • Page 4: Specifications

    MSR2012 1.4 Specifications: - electrical parameters (tab.2) - mechanical parameters (tab.3) - operating parameters (tab.4) Electrical parameters (tab. 2). Mains supply 20V÷22V AC 50VA min. (e.g. AWT5161820, AWT037) Current up to 2,5A max. Power frequency 50Hz Power 34 W Efficiency 11V÷...
  • Page 5: Installation

    MSR2012 2. Installation. 2.1. Requirements. The buffer PSU module is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the II-nd environmental class, with normal relative humidity (RH=90% maximum, without condensing) and temperature from -10°C to +40°C.
  • Page 6: Operation And Use

    CAUTION! The power supply module unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl...